DATA STORAGE PROGRAM
Store data
For your convenience, I-Peak 6 has a data storage and load program. It can store fi ve battery
data representing the respective specifi cations of batteries. You can call back the data when
charging or discharging without setting up the program again.
Select PROGRAM SELECT SAVE DATA from the main menu. Press "Start/Enter" key to make
values blink, and use "INC"or"DEC" to set up the parameter.
PROGRAM SELECT
SAVE DATA
Start
Data
Enter
number
SAVE [01]
NiMH
14.4V
3000mAh
Voltage
Start
Enter
NiMH CHARGE At*
CUR LIMIT 5.0A
<"DEC"
"INC">
<"DEC"
NiMH DISCHARGE*
1.0A
11.0V
<"DEC"
"INC">
<"DEC"
NiMH CYCLE
DCHG>CHG
Start
Enter > 3 sec
<"DEC"
Save ...
16
When it approaches to the end, you can see the capacity
1314mAh
of the battery being charged or discharged. You can press
1430mAh
"INC"or"DEC" key to display result of each cycle.
Setting of the parameter in this screen will not affect the charge and discharge
process. They just represent the specifi cation of the battery. The following
screens will automatically be displayed matched with the battery type you
set up. The example is NiMH battery pack, including 12 cells, the capacity is
3000m Ah.
Set up the charge current in the manual mode, or current limit in the auto
Capacity
mode. Press "INC"and"DEC" key simultaneously to make the current fi eld
blink to switch the charge mode.
-
+
"INC">
Set up the discharge current and fi nal voltage.
-
+
"INC">
*
Set up the charge/ discharge sequence and cycle number.
3
-
+
"INC">
Saving the data