Télécharger Imprimer la page

Ferroli EGEA 200 HT Manuel D'utilisation, Installation Et Entretien page 114

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Parameter Description
Tank upper probe temperature for heating
P22
element stop in photovoltaic mode
P23
Photovoltaic supplement
P24
Operating mode during Off-peak
P25
Offset for tank upper probe
P26
Offset for tank lower probe
P27
Inlet air probe offset
P28
Offset for defrost probe
P29
Anti-legionella cycle activation time
Hysteresis on upper tank probe for heating
P30
element operation
Working time of heat pump in Automatic
P31
mode for calculating heating speed
Threshold on tank lower probe for heating
P32
element switch-on in Automatic mode
P33
EEV use
Overheating calculation interval for EEV
P34
with automatic control
Overheating set-point for EEV with
P35
automatic control
Desuperheating set-point for EEV with
P36
automatic control
P37
EEV opening step during defrosting (x10)
EEV minimum opening step with automatic
P38
control (x10)
P39
EEV control mode
EEV initial opening step with automatic
P40
control / EEV opening set-point with manual
control (x10)
P41
AKP1 threshold for KP1 gain
P42
AKP2 threshold for KP2 gain
P43
AKP3 threshold for KP3 gain
P44
EEV KP1 gain
P45
EEV KP2 gain
P46
EEV KP3 gain
Max. inlet air temperature for heat pump
P47
operation
Min. inlet air temperature for heat pump
P48
operation
Inlet air temperature threshold for setting the
P49
electronic fan speed or two-speed AC
Tank lower probe temperature for frost
P50
protection
P51
EC evaporator fan upper speed set-point
P52
EC evaporator fan lower speed set-point
P53
EC evaporator fan defrost speed setpoint
P54
Low pressure switch bypass time
Band 1 evaporator temperature proportional
P55
regulation
Differential temperature with activation of
P56
maximum speed
Differential temperature with deactivation of
P57
maximum speed
114
EN
Range
30÷80°C
0 = function excluded
1 = enabled
0 = function excluded
1 = ECO 2 = Automatic
-25÷25°C
-25÷25°C
-25÷25°C
-25÷25°C
0÷23 hours
2÷20°C
10÷80 min
0÷20°C
0 = not used
1 = used
20÷90s
-8 ÷15°C
60÷110°C
5÷50
3~45
0 = automatic
1 = manual
5÷50
-10÷10°C
-10÷10°C
-10÷10°C
-10÷10
-10÷10
-10÷10
30÷50°C
-10÷10°C
10÷40°C
0÷15°C
60÷100%
10÷60%
0÷100%
1÷240 min
1÷20°C
P57÷20°C
1°C÷P56
cod. 3541T590 - Rev. 05 - 12/2021
EGEA
Default
75°C
0
0
0°C
0°C
0°C
0°C
23 hours
7°C
30 min
4°C
0
30 s
4°C
88°C
15
9
0
25
-1°C
0°C
0°C
2
2
1
43°C
4°C
25°C
12°C
65%
40%
50%
1
4°C
2°C
1°C
200 HT - 260 HT
Notes
Modifiable
Modifiable
Modifiable
Modifiable
Modifiable
Modifiable
Modifiable
Modifiable
Modifiable
Modifiable
Modifiable
Modifiable (1)
Modifiable (1)
Modifiable (1)
Modifiable (1)
Modifiable (1)
Modifiable (1)
Modifiable (1)
Modifiable (1)
Modifiable (1)
Modifiable (1)
Modifiable (1)
Modifiable (1)
Modifiable (1)
Modifiable (1)
Modifiable
Modifiable
Modifiable (1)
Modifiable
Modifiable (1)
Modifiable (1)
Modifiable (1)
Modifiable (1)
Modifiable (1)
Modifiable (1)
Modifiable (1)

Publicité

loading

Ce manuel est également adapté pour:

Egea 260 ht