Maintenance
Maintenance
• 21 Day Maintenance Cycle
- Refill propane tank. 20 lb (9.07 kg) propane tank lasts
approximately 21 days with 24-hour/7-days operation.
- Replace Octenol or Lurex3 cartridge.
See cartridge label for instructions.
- Empty or replace bug bag.
- Utilize the Quick Clear adapter at every tank change.
• Periodically wipe down the outside of the trap
with a clean, water damp cloth.
• Replace your 4 "C" Batteries every season.
Note: Bug bags should be replaced when half full. You can find all your accessory
Maintenance Schedule
Possible Cause
Example
Purchase Date
April 1st
Register Warranty
April 1st
Start Up Date
April 1st
SERVICE:
Seasonal Tune-Up
MAINTENANCE:
Propane & Octenol/Lurex3 Cartridge Change
April 21st
Quick Clear Cartridge
April 21st
Propane & Octenol/Lurex3 Cartridge Change
May 11th
Quick Clear Cartridge
May 11th
Propane & Octenol/Lurex3 Cartridge Change
May 31st
Quick Clear Cartridge
May 31st
Propane & Octenol/Lurex3 Cartridge Change
June 20th
Quick Clear Cartridge
June 20th
Propane & Octenol/Lurex3 Cartridge Change
July 10th
Quick Clear Cartridge
July 10th
SERVICE - WINTERIZATION
Discard Bug Bag & Octenol/Lurex3
Cartridge
Cover Trap Trumpet to avoid
nesting insects
Keep in garage or shed
9
Propane Tank Changing Tips
When attaching the regulator knob to a tank after a tank change,
be sure to fully tighten the regulator knob onto the tank. No need
to use tools, but do turn the knob as far as possible by hand.
When this is done, loosen the knob 1/4 turn, then re-tighten to
maximize seal.
The purpose for this is to fully engage the regulator onto the tank. If
the regulator is not fully engaged, the flow of gas may be restricted
to the point where the trap will show a gas empty code. If this
occurs, press the off button, close the tank valve, and remove the
regulator from the tank. Re-attach the regulator and try again.
needs at your local hardware or home improvement store.
Season 1
Season 2
Season 3
March 15th
Easy Quick Clear Valve
Important: Extinguish all smoking materials prior to
use of Easy Quick Clear Valve. Do not stand directly
behind the Quick Clear cartridge during operation.
Use of PROTECTIVE eyewear is recommended.
Important: Shut down your trap. Let fan run until it
stops before using Quick Clear Cartridges (about 5
minutes).
Quick Clear is recommended for regular maintenance to
remove built-up contaminants.
Recommended for use at every tank change. Also
recommended for use before seasonal storage to avoid
build up of contaminants during the off-season.
Instructions for "Easy Quick Clear Valve" maintenance
procedure shall be provided on a label attached to trap
where easily visible by user.
The Easy Quick Clear Valve is a threaded knob located on
Season 4
the back of your trap. It should be used with the adapter
included with your trap, and a threaded Quick Clear
cartridge available at your local hardware or home
improvement store.
1. Important: Shut down your trap. Let fan run until it
stops before using Quick Clear Cartridges (about 5
minutes).
2. Close the propane tank valve by turning to the "OFF"
position. (Turn the tank valve clockwise.)
3. Remove the protective cap from Easy Quick Clear valve
located in the back of the trap.
4. Hand-screw the Quick Clear adapter on to Quick Clear
valve, until finger tight.
5. Hand-screw the Quick Clear cartridge into the Quick
Clear adapter clockwise until hand tight while holding
the adapter in place. Important: Do not over-tighten.
6. While holding the adapter in place slowly unscrew
Quick Clear cartridge up to 1/4 turn only in counter
clockwise direction from the Quick Clear adapter only.
The strong flow of compressed air lasts approximately
45 seconds. Be sure to allow Quick Clear cartridge to
run out completely. (Hissing will stop when cylinder is
empty. Quick Clear cartridge will be cold to the touch.)
7. Unscrew the Quick Clear cartridge to remove. Discard
empty Quick Clear cartridge after use; it is not reusable
or refillable.
8. Unscrew the Quick Clear adapter to remove. Use
caution when removing Quick Clear adapter and
cartridge, as some compressed air may come out at
this time. Remember to keep the Quick Clear adapter
for future use.
9. Replace Easy Quick Clear Valve protective cap, and
proceed with normal start up of your trap.
Step 4
First hand-screw the Quick Clear adapter onto the valve.
Step 5
While holding the adapter in place, screw the Quick Clear
cartridge into Quick Clear adapter.
Step 6
To start cleaning process, while holding Quick Clear
Adapter in place, unscrew the Quick Clear cartridge
1/4 Turn Only.
Step 7
Unscrew the Quick Clear cartridge first, then unscrew Quick
Clear adapter and discard the spent Quick Clear cartridge.
Remember to keep the Quick Clear adapter for future use.