Télécharger Imprimer la page

Mosquito Magnet INDEPENDENCE Manuel De L'utilisateur page 5

Masquer les pouces Voir aussi pour INDEPENDENCE:

Publicité

Les langues disponibles

Les langues disponibles

Set-Up
Propane Tank Installation
1. After trap is placed in its ideal location,
place propane tank onto the base.
2. Making sure propane tank is fully closed, attach
propane regulator hose to propane tank. Secure
tightly by hand. Do not use tools.
3. Turn propane on by slowly turning valve counter-
clockwise. Take care not to turn too quickly to avoid
engagement of safety valve.
DO NOT MOVE TRAP WITH TANK ATTACHED!
TANK MUST BE DISCONNECTED FROM REGULATOR
BEFORE TRAP IS RELOCATED TO AVOID DAMAGE
TO REGULATOR AND/OR TRAP. BE ADVISED,
DAMAGE CAUSED FROM FAILURE TO COMPLY
WITH THIS INSTRUCTION IS NOT COVERED
UNDER WARRANTY.
7
Step 1 – Propane Tank Placement
Step 2 – Attach Regulator
Step 3 – Slowly Open Valve
Instructions
**READ MANUAL BEFORE STARTING**
Starting Instructions
It is recommended that you read the entire manual
before starting the Mosquito Magnet
trap.
®
1. Insert Octenol or Lurex3 cartridge in compartment per
instructions in cartridge packaging.
2. Install 4 "C" Batteries into the rear compartment.
3. Connect regulator to propane tank.
4. Slowly turn propane tank valve on.
5. Push "ON/OFF" switch to ON Position. LED light will
turn solid orange indicating warm-up. After 15 - 25
minutes, trap LED light will turn solid green indicating
the trap is running at full capacity.
Shut Down Instructions
To shut down the Mosquito Magnet, simply close the valve
on the propane tank and push "off" button on back of
power head.
When Not In Use
If the unit is not in use, the gas must be turned off at the
supply cylinder. Storage of this unit indoors is permissible only
if the cylinder is disconnected and removed. Cylinders must
be stored outdoors, out of reach of children and must not be
stored in a building, garage or any other enclosed area.
End of Season Storage
Push ON/OFF switch to OFF position to shut down the
trap. The LED light will go out and the fan will continue
running until trap is cool. Close the propane tank valve
and disconnect regulator. Remove the 4 "C" batteries
and discard.
Any open Mosquito Magnet® Octenol or Lurex3
cartridges should be removed and discarded. See
cartridge label for disposal instructions. The bug bag
should also be discarded prior to storing the trap.
STORAGE: The trap should be stored indoors in a garage
or shed in the off-season. Cover trumpet to prohibit
insects from nesting. Cover unit with trap cover or with a
tarp and secure tightly at the bottom to keep out dust,
spider webs and other debris.
NOTE: It is recommended that you use the Quick Clear
adapter before seasonal storage to avoid build-
up of contaminants during off-season.
(see page 10).
For Best Results (unit must run for 24 hours/day)
• Your trap will begin capturing immediately with
significant reduction in the mosquito population in
7-10 days. Allow 4 weeks to significantly reduce the
mosquito population in your yard.
• Allow trap to cool for 5 minutes before re-start.
• Never spray insecticide in or around trap.
• Trap can be left running in the rain, but do not place
trap directly above a water source (sprinklers, hose,
etc.).
• If using lime or fertilizer compounds, be sure to shut
down the trap first to prevent dust or fine mist from
being drawn into trap and clogging bug bag.
Warning: Improper installation, adjustment, alteration, service
or maintenence can cause injury or property damage. Read the
installation, operating and maintenence instructions thoroughly
before installing or servicing this equipment.
Caution: The gas pressure regulator provided with this
appliance must be used. This regulator is set for an outlet
pressure 11.0 in. water column.
The gas supply must be turned off at the LP-Gas supply
cylinder when this appliance is not in use.
8