Télécharger Imprimer la page

Briteq LDP ACCUSPOT 7TC Mode D'emploi page 7

Publicité

Les langues disponibles
  • FR

Les langues disponibles

ENGLISH
INSTALLING THE (OPTIONAL) W-DMX MODULE
Important: The electrical installation should be carried out by
qualified personal only, according to the regulations for
electrical and mechanical safety in your country.
 Unpack the "LDP-WDMX-ACCUSPOT" module (W-DMX module): it
consists of an antenna with nut and the actual W-DMX PCB.
 Switch the projector off and remove the mains cable.
 On the projector: remove the 4 screws of the blind plate where the W-
DMX module will be installed.
 Remove the blind plate and follow the pictures below.
A. The blind plate has a plastic cover cap: use a screw driver to push this cover cap and remove it.
B. Install the antenna in the hole and fix it firmly but gently with the nut.
C. Put the PCB in place and fix it to the metal plate using the 4 screws.
D. Press the connector of the antenna cable on the PCB (you will notice a small click)
E. Before you put the module back in the projector, you have to connect it: Inside the projector
compartment you will see a grey flat cable with connector.
Install the flat cable on the connector of the W-DMX module: CAREFULLY check picture E, it is VERY
important that the RED LINE on the flat cable is exactly as on the picture!
 Put the W-DMX module back in place and fix it using the 4 screws.
 Done!
Check the next chapter to learn how to assign and use wireless DMX.
ELECTRICAL INSTALLATION
Important: The electrical installation should be carried out by qualified personal only,
according to the regulations for electrical and mechanical safety in your country.
Note: In the explanations below we assume that you will operate the projectors with the internal battery
which is already fully charged. If you want to use them with a mains cable, simply connect all projectors to
the mains using the supplied power cable.
Electrical installation for 1 standalone unit:
 Switch the projector on using the power switch (11). The unit starts working immediately in the last
selected stand-alone mode.
 Refer to chapter HOW TO SETUP to learn how to switch between different working modes.
Remark: You can connect a JBS CA-8 remote controller to the unit if you want to have more control.
Electrical installation for two or more units in master/slave:
 Connect 2 to maximum 16 units together using good quality balanced microphone/DMX cables. The unit
that has no cable connected to its DMX-input is the "master", the others are the slave units.
 Make sure that all units are switched on.
 Refer to chapter HOW TO SETUP for more information.
 Done!
BRITEQ
®