1)
No power to pressure switch due to blown fuses,
open switches or loose connections.
2)
Pump pressure switch not closed.
b)
Pump fails to deliver water:
1)
Pump not completely primed.
2)
Suction lift is too great.
3)
Foot valve is either not submerged, buried in the mud
or plugged.
c)
Pump loses prime:
1)
Air leaks in suction line.
2)
Well draws down too far.
3)
Faulty foot valve.
1
Item #
305584001
305584002
305584003
305584004
305584005
305584006
305584007
305584008
305584009
305584010
305584011
305584012
305584013
305584014
Replacement Parts
12
Item Description
Case Kit
Seal Plate Kit
Nozzle/Venturi Kit
Nozzle/Venturi Kit
Nozzle/Venturi Kit
Overhaul Kit
Overhaul Kit
Overhaul Kit
Impeller/Diffuser Kit
Impeller/Diffuser Kit
Impeller/Diffuser Kit
Shaft Seal Kit
Gasket/Hardware Kit
Pressure Switch Kit
d)
Pump delivers water but not at rated capacity:
1)
Leaks in suction or discharge line.
2)
Foot valve, suction line, impeller or nozzle are
partially plugged.
3)
Suction lift is greater than recommended.
4)
Improper impeller rotation or low speed.
5)
Venturi or diffuser is plugged.
6)
Motor is wired for improper voltage.
7)
Motor does not come off starting windings (improper motor
switch adjustment).
e)
Pump starts and stops too often:
1)
Faulty air volume control.
2)
Air leaks in tank above the water level.
3)
Incorrect setting on pressure switch.
4)
Tank is water logged or too small for application.
2 3
4
5
6
7
Where Used
All RJS-PREM Models
All RJS-PREM Models
RJS-50-PREM
RJS-75-PREM
RJS-100-PREM
RJS-50-PREM
RJS-75-PREM
RJS-100-PREM
RJS-50-PREM
RJS-75-PREM
RJS-100-PREM
All RJS-PREM Models
All RJS-PREM Models
All RJS-PREM Models
5
9
8
10
11
11
11
11
Contents
9
2
3, 7, & 8
3, 7, & 8
3, 7, & 8
3, 4, 5, 6, 7, & 8
3, 4, 5, 6, 7, & 8
3, 4, 5, 6, 7, & 8
3, 5, & 6
3, 5, & 6
3, 5, & 6
3 & 4
3, 10, 11, & 12
1