Connections
Interventions must only be made by technical personnel and with suitable tools.
Always switch off the power supply before working on the system.
Fit a dirt collector if necessary to protect against faults.
Ensure compliance of the operating conditions with the performance data of the unit.
Avoid pressure build-up in the exhaust air ducts by large silencers.
ATTENTION!
Pipes or valves in systems under pressure must not be disconnected!
Electrical connection
Rectangular connector
Fig.: Connection possibilities of type 6104 pilot valves
Servo control valve Type 6104
Read the voltage, electrical power, type of protection and current from the rating plate!
voltage tolerance ±10 %
With 100% duty cycle and maximum ambient temperature the coil heats up
in the single version to approx. + 105 °C
in a block to approx. + 120 °C
Ensure a long service life for the pilot valve with 5µ filtering.
NOTE
ATTENTION!
Note the voltage! Fit a rectifier in series without fail for alternating voltage!
I
NSTALLATION
Stranded conductor
connection
, C
OMMISSIONING AND
Circular connector
M
AINTENANCE
6524/6525 - 13