Instructions for Series 5 / 10
GB
Configuration and Set-up
4.2. Table of configuration step codes
Code
Parameter
Reset and restore default settings:
00
* * * *
In case of a reset, the entire memory is deleted and all parameters
are adapted to the default settings. A reset only takes a few
seconds. A high-pitch beep can be heard during reset.
Change security code: Default setting: 0 0 0 0
01
new code [beep] new code
The security code has four digits. Enter the new code twice in
succession. The default is: 0 0 0 0.
Please note: To avoid an unauthorised configuration, the default
security code must be changed.
Answering a call: Default setting: 1
03
0 = manually by pressing a button
1 = automatically
Input delay for direct call buttons: Default setting: 0
04
0 = none
1 = 1 second
9 = 9 seconds
During this configuration step, it takes a few seconds until the
device has confirmed the correct entry. When the input delay is
activated, the direct call buttons must be pressed for at least the
set time until the direct call is triggered.
Connection interval: Default setting: 3
05
0 = unlimited (i.e. limited to approx. 8 hours)
1 = limited to 1 minute
9 = limited to 9 minutes
After expiration of this time, the
connection will be terminated automatically.
Volume: Default setting: 7
06
0 = soft
9 = loud
This configuration step adjusts the volume in full duplex
operations mode (standard mode).
50
Confirmation
#
#
#
#
#
#
#
#
#
#
#
#
www.behnke-online.com