Respect the position of the shelves as indicated, (Rif. 1) modification
causes cabinet malfunctioning.
DO NOT climb for any reason on the front of the cabinet to facilitate
loading operations (Rif. 16). Use a suitable ladder up to norm to reach
the loading points. It is the Client's responsibility to check that all the
operations be performed safely and in accordance to the norms in force.
The maximum admissible load on the decks is approximately 160 kg/m
350 kg/m
DO NOT load the cabinet while keeping all the doors simultaneously open
(Rif. 21);
When loading the goods, do not keep the doors open too long.
It is the client's responsibility to use the communication instruments most
appropriate to warn consumers during purchases that they must not climb on
the front to reach the products.
To avoid that goods slide off the tilted decks, always use the containment side
panels.
We recommend to first deplete the goods that have been in the cabinet longer
compared to newly added ones (rotation of the food produce);
15.Defrosting and water drainage (Rif. 22)
The Wengen refrigerated cabinet line is fitted with an electric defrosting system (via
refrigeration cycle stop - n° 2 x 30 min. defrosting periods daily - and the use of
armoured electrical resistances).
15_1.Water drainage:
To evacuate the defrost water you must:
provide a drain to ground with a slight slope;
install the syphon supplied between the drain pipe of the cabinet and the
connection to ground.
hermetically seal the area of drainage to ground.
In this way, it is possible to avoid: bad odors inside the cabinet, dispersion of
refrigerated air, and the possible malfunction of the cabinet due to humidity.
Periodically check that hydraulic connections are perfectly efficient, contacting a
qualified installer.
16.Lighting
The lighting inside the cabinet is obtained by fluorescent bulbs (58W 4000K) positioned
vertically behind the cabinet frame uprights. The light switch is positioned at the base
of the cabinet.
The reactors, the starters and the condensers are positioned on the roof of the cabinet.
Wengen - 2 Door: n° 3 bulbs
Wengen - 3 Door: n° 4 bulbs
Wengen - 4 Door: n° 5 bulbs
Wengen - 5 Door: n° 6 bulbs
To increase energetic saving, the cabinet can be requested with low
consumption LED lights that allow:
reduced lighting consumption
reduced refrigerated load
duration of the lights for more than 6 years
uniform lighting intensity and colour
improvement of the lighting as temperature drops.
17.Replacing the lamps (Rif. 23)
To replace the lamps, proceed as follows:
Remove electric power supply from the cabinet.
Press on the spring (1) at the base of the bulb, releasing the protective casing.
34
2
in the tank.
2
and
05060130 00 26/04/2012