Repairs at the unit
17. Carefully tighten retainer nut (5) with adjusting wrench
18. Slide the top of the piston (3) into the T-slot (9) on the
slider assembly (4).
19. Position the pump manifold (2) underneath the gear unit
housing and push up until it rests against the gear unit
housing.
20. Attach pump manifold (2) to the gear unit housing.
21. Screw pump manifold (2) tightly to gear unit housing.
22. Lubricate O-ring (Fig. 13, Item 6) between pump manifold
(2) and inlet valve housing with machine grease. Screw
inlet valve housing to the pump manifold.
11.4

ProSpray 3.25 connection diagram

Blue
Switch
Blue
P/N 0522053
Ground
Surge suppressor
Ground
P/N 0522052
Ground
Brown
Brown
Black
Blue
White
P/N 0551758
GB
Unit on high-rider cart:
23.
Thread the siphon tube into the inlet valve and tighten
securely. Make sure to wrap the threads on the down
tube with Teflon tape before assembly. Replace the return
hose into the hose clip on the siphon tube.
Unit on stand:
Insert the elbow on the siphon assembly into the bottom
of the pusher stem housing. Push the retaining clip up
into the groove inside the foot valve housing to secure the
siphon assembly in position. Place the return tube over
the return tube fitting and secure with the clip.
24. Install front cover.
EMI Filter
Power Cord
Fuse block
Fuse
Black
Red
Black
White
Red
Black
Motor
38
Capacitor
Motor controller
Red (+)
Black (-)
L.E.D.
Hall sensor
Potentiometer
Display wire
assembly
Pressure sensor