IO-Link DA interface – Operating instructions

12 IO-Link D/A interface signal connections

The IO-Link D/A interface includes two sockets for the connection of one mini I/O terminal each, as well as
one I-Port interface for connection to an IO-Link master.
IO-Link D/A interface
Electrical data
Operating voltage range/nominal voltage
Supply voltage range, outputs/nominal voltage
Undervoltage detection for output voltage
Power consumption
Connector sockets:
Number of outputs
Output load capacity
Short-circuit protection
Number of inputs
Trigger level of the digital inputs
Filter
Communication interface
Mechanical data
Dimensions
Weight
Degree of protection
With cover plate
Mounted in 19" rack with CTEU
CE marking
Permissible ambient temperature during operation
General technical data, IO-Link D/A interface
36
18 ... 30 V DC/24 V DC
18 ... 30 V DC/24 V DC
< 19 V DC:
emergency notification is switched to the I-Port.
< 3 VA
2 x D-SUB 15 high density, female,
5-pin M12 plug, A coded
8 digital outputs, 24 V DC, short-circuit-proof
2 analogue outputs, 0 ... 10 V DC, 12 bit
resolution
1000 mA per digital output
50 mA per analogue output
A total of up to 1200 mA can be switched.
Yes
8 digital, 24 V DC,
4 analogue, 0 ... 10 V DC
12 bit resolution
Switch on: > 16 V
Switch off: < 8 V
2 ms
I-Port (IO-Link)
91.5 x 128.3 x 30mm
240 g
IP 20
IP 40
In accordance with EU EMC directive
5 ... 40° C
© Festo Didactic 8038560