note!
The seal of the AirLINE Quick adapter must be placed into the
groove without being damaged before installing the adapter on the
control cabinet base.
→
Attach the stability plate from the outside to the control cabinet
base or wall to prevent distortion and fix with M5 screws.
Fig. 8:
Attaching the stability plate
14
Screws
Stability plate
english
Type 8644
Structure and installation
8.3.3. d imensions of the flange images for
airline Quick
158 ± 0.4
t >= 1.5
54 ± 0.3
155 ± 0.4
(192)
Fig. 9:
Dimensions: 8-fold adapter
Space requirements
for reinforcing frame
on the outside