To disable the test function to check the power circuit good conditions:
1 Move Dip-switch 3 of the selector switch DP1 to ON, all others to OFF.
2 Press button PGM, wait that LED PROG switches off.
3 Move the Dip-switches to the original position.
4 With the deactivated function, even in the case of faulty power circuit, the control unit will execute the
controls.
The Dip-switches "Bypass" allow to short-circuit Normally Closed inputs which are not in use.
DIP 1
STOP Input
Off: Enabled Input
On: Disabled Input
DIP 2
FTCC Input
Off: Enabled Input
On: Disabled Input
DIP 3
FCA1 Input
Off: Enabled Input
On: Disabled Input
DIP 4
FCA2 Input
Off: Enabled Input
On: Disabled Input
DIP 5
FCC1 Input
Off: Enabled Input
On: Disabled Input
DIP 6
FCC2 Input
Off: Enabled Input
On: Disabled Input
DIP 7
FTCA Input
Off: Enabled Input
On: Disabled Input
DIP 8
Not in use
The control unit is complete with a series of self-diagnostic LED's which allow checking of all functions:
LED PED
It switches on when the PEDONALE (Pedestrian) Input is activated
LED CH
It switches on when the CHIUDE (Close) Input is activated
LED AP
It switches on when the APRE (Open) Input is activated
LED P.P.
It switches on when the Passo-Passo (Step-by-Step) Input is activated
LED STOP
It switches off when the STOP Input is activated
LED FTCC
It switches off when photocells are not aligned or obstacles are present during closure
LED FCA1
It switches off when Motor 1 Opening Photocell Input is activated
LED FCA2
It switches off when Motor 2 Opening Photocell Input is activated
LED FCC1
It switches off when Motor 1 Closing Photocell Input is activated
LED FCC2
It switches off when Motor 2 Closing Photocell Input is activated
LED FTCA
It switches off when photocells are not aligned or obstacles are present during opening
LED POWER
Shows mains power supply.
LED PROG
It flashes to show the micro-processor correct operation.
Functions of Dip-switch DP2 "BYPASS"
LED diagnostics