Input LED
Parameter
L6
Partial Open
L7
Maintenance
warning
L8
Fault list
Note: "
" represents the factory setting
Note (1): Automatically regulates the force required, maintaining a minimum guaranteed force level.
Note (2): Automatically regulates the force required.
All parameters can be adjusted as required without any contraindications, only the "Obstacle detection sensitivity" and "Motor force control"
may require special attention:
• Use of high force values are not recommended to compensate for the fact that the leaf has anomalous points of friction; excessive force
may impair the safety system and damage the leaf.
• If the "Obstacle detection sensitivity" is used in support of the system for impact force reduction, after each adjustment the force mea-
surement procedure must be performed, as envisaged by standard EN 12445.
• Wear and atmospheric conditions that influence movement of the gate; force settings should be checked periodically.
7.2.4) Level two programming (adjustable parameters)
The adjustable parameters are factory set as shown in the table 9, with: "
10. Follow the procedure carefully, as there is a maximum time of 10 seconds between pressing one key and another. If a longer period of
time lapses, the procedure will finish automatically and memorize the modifications made up to that stage.
Tabella 10: changing the adjustable parameters
1.
Press and hold key [Set] (approx. 3 s)
2.
Release the [Set] key when L1 LED starts flashing
3.
Press key [▲] or [▼] to move the flashing LED onto the input LED representing the parameter to
be changed
4.
Press the key [Set] and hold it down during step 5 and 6
5.
Wait approx. 3 seconds, after which the LED representing the current level of the parameter to be
modified will light up.
6.
Press key [▲] or [▼] to move the LED representing the parameter value.
7.
Release the key [Set]
8.
Wait 10 seconds before leaving the programme to allow the maximum time to lapse.
Note: Points 3 to 7 can be repeated during the same programming phase in order to set other parameters
Led (level)
L1
0,5 mt
L2
1 mt
L3
1,5 mt
L4
2 mt
L5
2,5 mt
L6
3 mt
L7
3,4 mt
L8
4 mt
L1
Automatic (based on seriousness of
manoeuvres)
L2
2.000
L3
4.000
L4
7.000
L5
10.000
L6
15.000
L7
20.000
L8
30.000
L1
Manoeuvre 1 result (most recent)
L2
Manoeuvre 2 result
L3
Manoeuvre 3 result
L4
Manoeuvre 4 result
L5
Manoeuvre 5 result
L6
Manoeuvre 6 result
L7
Manoeuvre 7 result
L8
Manoeuvre 8 result
Value
The measurement of the partial opening. Par-
tial opening can be controlled with the 2nd
radio command or with "CLOSE", if the "Clo-
se" function is present, this becomes "Partial
open".
Adjusts the number of manoeuvres after
which it signals the maintenance request of
the automation (see paragraph "7.4.4 Main-
tenance warning").
The type of defect that has occurred in the
last 8 manoeuvres can be established (see
paragraph "7.6.1 Malfunctions archive").
" However, they can be changed at any time as shown in Table
Description
Example
SET
3s
L1
SET
or
SET
or
SET
10s
15