Kozy Heat Fireplaces KIT KOMFORT ZONE KZK-1510A Mode D'emploi

Pour utiliser avec le foyer au gaz à évacuation directe callaway-50 nº clw-50
Masquer les pouces Voir aussi pour KIT KOMFORT ZONE KZK-1510A:

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

KOMFORT ZONE KIT
#KZK-1510A
For use with the Callaway-50 #CLW-50
Direct Vent Gas Fireplace
Starting Serial Number: 19 501780 50
English and French installation manuals are available through your
local dealer. Visit our website www.kozyheat.com.
Les manuels d'installation en français et en anglais sont disponibles
chez votre détaillant local. Visitez www.kozyheat.com .
1.0 INTRODUCTION .......................................................................3
1.1 Kit Contents.......................................................................................... 3
1.2 Suggested Configurations .............................................................. 4
1.3 Dimensions and Overview ............................................................. 5
1.4 Air Duct Pipe Run ............................................................................... 6
2.0 FRAMING AND CLEARANCES ................................................7
2.1 Clearance to Sprinkler ...................................................................... 7
2.2 Framing.................................................................................................. 8
2.3 Minimum Shelf Requirements ...................................................... 9
3.0 FACING AND FINISHING .......................................................10
3.1 Non-combustible Requirements ................................................10
3.2 Combustible Finish ..........................................................................11
3.3 Hearth and Mantel Clearances ....................................................13
4.0 INSTALLATION .......................................................................14
Hussong Manufacturing Co., Inc.
P.O. Box 577, 204 Industrial Park Drive
Lakefield, MN 56150-0577, USA
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
HUSSONG MANUFACTURING CO., INC.
READ ALL THESE STEPS
BEFORE STARTING INSTALLATION.
LEAVE THESE INSTRUCTIONS WITH THE
APPLIANCE.
This kit must be installed by a qualified installer,
service agency, or gas supplier at the time of
the heater installation. These instructions must
be used in conjunction with the installation and
operation manual provided with the appliance.
Please read the appliance owner's manual
completely before performing any procedures in
these instructions.
This optional convection duct kit redistributes the
warm air flow away from the fireplace opening to
a more desirable location using natural convection
without the use of a fan. The warm air flow may be
relocated to a position higher up the wall, out the
sidewalls, or even to an adjacent room. The result
is much cooler wall temperatures above the fire-
place opening for locating televisions, artwork, etc.
Rev. 3, 4/20

Publicité

Chapitres

Table des Matières
loading

Sommaire des Matières pour Kozy Heat Fireplaces KIT KOMFORT ZONE KZK-1510A

  • Page 1: Table Des Matières

    KOMFORT ZONE KIT #KZK-1510A For use with the Callaway-50 #CLW-50 HUSSONG MANUFACTURING CO., INC. Direct Vent Gas Fireplace Starting Serial Number: 19 501780 50 INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference. English and French installation manuals are available through your READ ALL THESE STEPS local dealer.
  • Page 3: Introduction

    (4) take o collars included Figure 1.1, #KZK-1510A #KZK-410-6 (4) - 10’ x 6” (aluminum ex) listed to UL-181Class 0 Air Duct Figure 1.2, #KZK-410-6 Komfort Zone Kit #KZK-1510A R.3 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces INTRODUCTION 3...
  • Page 4: Suggested Configurations

    The (2) plenums and the (2) air grilles in this kit are required and both must be installed. #KZK-1510A side wall outlet #KZK-1510A rear wall outlet Figure 1.3, #KZK-1510A Suggested Configurations 4 INTRODUCTION Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces Komfort Zone Kit #KZK-1510A R.3...
  • Page 5: Dimensions And Overview

    If you are mounting the plenum above the fireplace between 10’ (3m) to 20’ (6m) you will need (2) #KZK-410-6 kit and (1) #KZK-CPL6 coupler kit. Figure 1.5, #KZK-1510A Overview Komfort Zone Kit #KZK-1510A R.3 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces INTRODUCTION 5...
  • Page 6: Air Duct Pipe Run

    WHEN INSTALLING AIR DUCT PIPE MAINTAIN A MINIMUM 4" VERTICAL RISE FOR EVERY 12" HORIZONTAL RUN Minimum bend radius=5” (127mm) 4” (102mm) 12” (304mm) Figure 1.6, Minimum Vent Pipe Run - only (1) plenum shown 6 INTRODUCTION Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces Komfort Zone Kit #KZK-1510A R.3...
  • Page 7: Framing And Clearances

    Please follow local building codes to determine what temperature setting is relevant for your installation. 60” (1524mm) Ceiling ½ ” Sprinkler Head (89mm) Figure 2.1, KZK Clearance to Sprinkler Komfort Zone Kit #KZK-1510A R.3 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces FRAMING AND CLEARANCES 7...
  • Page 8: Framing

    (1638mm) ½ ” (1130mm) 22” 76” (559mm) ½ ” (1930mm) (1638mm) ½ ” 22” (1130mm) (559mm) Figure 2.4,CLW-50 Unit Wall Enclosure Rough Opening 8 FRAMING AND CLEARANCES Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces Komfort Zone Kit #KZK-1510A R.3...
  • Page 9: Minimum Shelf Requirements

    7” (178mm) 18” (457mm) 18” 22” (457mm) (559mm) Figure 2.5, Minimum Shelf Requirements Komfort Zone Kit #KZK-1510A R.3 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces FRAMING AND CLEARANCES 9...
  • Page 10: Facing And Finishing

    No Screws Allowed No Screws Allowed ¾ 13” ¾ ” 13” ” (330mm) (95mm) (330mm) (95mm) Figure 3.2, Minimum Non-combustible Finishing Dimensions Screw Locations 10 FACING AND FINISHING Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces Komfort Zone Kit #KZK-1510A R.3...
  • Page 11: Combustible Finish

    (301mm) ⁄ ” (301mm) NOT ALLOWED INSIDE MINIMUM SHELF ENCLOSURE Figure 3.3, #KZK-1510A Drywall Finish and Combustible Finishing Material up to 1" Thick Komfort Zone Kit #KZK-1510A R.3 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces FACING AND FINISHING 11...
  • Page 12 1” (25mm) thick Steel may be installed over Framing cement board Finishing Edge Fireplace Enclosure Floor Figure 3.4, #KZK-1510A Combustible Wall Finish 12 FACING AND FINISHING Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces Komfort Zone Kit #KZK-1510A R.3...
  • Page 13: Hearth And Mantel Clearances

    Finishing Edge 6” (152mm) 9” (229mm) ¾ ” (248mm) 12” (305mm) Fireplace Enclosure Floor Figure 3.6, Hearth and Mantel Clearances for No Surround Komfort Zone Kit #KZK-1510A R.3 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces FACING AND FINISHING 13...
  • Page 14: Installation

    Attach the piping from all (4) plenum take off collars to all (4) Figure 4.4, Air Grille Screw Location 14 INSTALLATION Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces Komfort Zone Kit #KZK-1510A R.3...
  • Page 16 KIT KOMFORT ZONE nº KZK-1510A Pour utiliser avec le foyer au gaz à évacuation HUSSONG MANUFACTURING CO., INC. directe Callaway-50 nº CLW-50 Début du numéro de série : 19 501780 50 INSTALLATEUR : Laissez ce manuel avec l’appareil. PROPRIÉTAIRE : Conservez ce manuel pour le consulter. English and French installation manuals are available through your LISEZ TOUTES CES ÉTAPES local dealer.
  • Page 18: Introduction

    (4) - section de 10 pieds x 6 po conduit exible (aluminium) homolgué UL-181, Conduit d’air De Classe 0 Figure 1.2, Item no KZK-410-6 Kit Komfort Zone nº KZK-1510A R.3 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces INTRODUCTION 3...
  • Page 19: Configurations Suggérées

    1.2 Configurations suggérées #KZK-1510A sortie murale adjacent #KZK-1510A sortie murale arrière Figure 1.3, Configurations suggérées du KZK-1510A 4 INTRODUCTION Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces Kit Komfort Zone nº KZK-1510A R.3...
  • Page 20: Dimensions Et Vue D'ensemble

    Si vous installez le plénum à plus de 10 pieds (3 m) et moins de 20 pieds (6 m) au-dessus du foyer, vous aurez besoin de deux (2) kits nº KZK-410-6 et du kit de coupleurs nº KZK-CPL6. Figure 1.5, Vue d'ensemble du kit KZK-1510A Kit Komfort Zone nº KZK-1510A R.3 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces INTRODUCTION 5...
  • Page 21: Installation Des Conduit D'air

    À TOUS LES 12 PO (30 CM) DE COURSE HORIZONTALE Rayon de courbure minimal=5” (127mm) 4” (102mm) 12” (304mm) Figure 1.6, Installation de conduits d'air de longueur minimale 6 INTRODUCTION Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces Kit Komfort Zone nº KZK-1510A R.3...
  • Page 22: Encadrement Et Dégagements

    à votre installation. 60” (1524mm) Tête de gicleur ½ ” au plafond (89mm) Figure 2.1, Dégagement au gicleur du kit KZK Kit Komfort Zone nº KZK-1510A R.3 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces ENCADREMENT ET DÉGAGEMENTS 7...
  • Page 23: Encadrement

    (1219mm) (1638mm) ½ ” (1130mm) 22” 76” (559mm) ½ ” (1930mm) (1638mm) ½ ” 22” (1130mm) (559mm) Figure 2.4, Encadrement et dégagement 8 ENCADREMENT ET DÉGAGEMENTS Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces Kit Komfort Zone nº KZK-1510A R.3...
  • Page 24: Dimensions Minimales D'installation Et Exigences Avec Étagère

    à une étagère murale ou une tablette encastrée. 7” (178mm) 18” (457mm) 18” 22” (457mm) (559mm) Figure 2.5, Requis d'une tablette d'étagère Kit Komfort Zone nº KZK-1510A R.3 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces ENCADREMENT ET DÉGAGEMENTS 9...
  • Page 25: Façade Et Finition

    ¾ ” 13” ” (330mm) (95mm) (330mm) (95mm) Figure 3.2, Emplacements de vis permis (pour matériaux incombustibles de finition de dimensions minimales 10 FAÇADE ET FINITION Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces Kit Komfort Zone nº KZK-1510A R.3...
  • Page 26: Matériaux De Finition Combustibles

    Cette installation n'est pas autorisée pour une tablette encastrée Figure 3.3, Revêtement en matêriau combustible et Matériaux de finition combustibles de 1 po d'épaisseur maximale Kit Komfort Zone nº KZK-1510A R.3 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces FAÇADE ET FINITION 11...
  • Page 27 Bord de nition du foyer Plancher d’enceinte du foyer Figure 3.4, Matériaux de finition murale combustibles avec le KZK-1510A 12 FAÇADE ET FINITION Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces Kit Komfort Zone nº KZK-1510A R.3...
  • Page 28: Dégagements De L'âtre Et Du Manteau

    9” (229mm) ” (248mm) 12” (305mm) Plancher d’enceinte du foyer Figure 3.6, Dégagements de l’âtre et du manteau pour une installation sans contour Kit Komfort Zone nº KZK-1510A R.3 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces FAÇADE ET FINITION 13...
  • Page 29: Installation

    Utilisez des bandes d’attache métalliques de type AllRound(R) (non fournies) comme support additionnel pour fixer solidement le plénum à l’encadrement. 14 INSTALLATION Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces Kit Komfort Zone nº KZK-1510A R.3...

Ce manuel est également adapté pour:

19 501780 50

Table des Matières