Kozy Heat Fireplaces KIT KOMFORT ZONE KZK-1510A Mode D'emploi page 12

Pour utiliser avec le foyer au gaz à évacuation directe callaway-50 nº clw-50
Masquer les pouces Voir aussi pour KIT KOMFORT ZONE KZK-1510A:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

3.2.2 Combustible Wall Finish
Figure 3.4 shows installation of combustible wall finish up to 1"
thick. This combustible material goes on any required non-
combustible materials as shown in Figure 3.1 on page 10.
This 1" (25mm) combustible material is able to go down to the
fireplace finishing edge.
See Figure 3.3 on page 11 for up to 1" (25mm) thick
combustible material installation around the KZK air discharge
grille.
Non-combustible zone
Combustible wall nish
up to 1" (25mm) thick
may be installed over
cement board
Finishing Edge
Figure 3.4, #KZK-1510A Combustible Wall Finish
12 FACING AND FINISHING
½
around pipe
Steel
Framing
Fireplace Enclosure Floor
Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces
" (13mm) clearance
Komfort Zone Kit #KZK-1510A R.3

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

19 501780 50

Table des Matières