4.2
Basic functions (see Table 4.11a for settings)
Parameters
1: Door and gate
The assigned output relay picks up when the loop is activated and drops out when the loop returns to a non-activated condition.
2: Barrier
The assigned output relay picks up when the loop is activated and drops out when the loop returns to a non-activated condition.
3: Quiescent current The assigned output relay drops out when the loop is activated and picks up again when the loop returns to a non-activated condition.
4: Direction logic
Output 1 switches if an object moves from loop 1 to 2. Output 2 switches if an object moves from loop 2 to 1. Both loops must be
activated for a short time. The outputs are reset again when loop 2 returns to a non-activated condition. Both loops must have re-
turned to a non-activated condition for another direction detection.
0: Loop 2
Loop 2 can be deactivated in a 2-loop device.
Relay response to malfunctions (see chapter 6 Troubleshooting):
A malfunction causes
1. Door/gate
the output relay to be
released. The alarm
systems
relay drops out.
4.3
Time functions , time unit
The relay picks up when the
loop is activated and drops
out when the loop is exited.
Activation pulse:
The relay picks up when the
loop is activated and drops
out again after the time t.
4.4
Sensitivity (see Table 4.11a for settings)
The sensitivity
(=Sensitivity) of the loop detector can be adapted in 9 stages:
= Factory setting.
4.5
Automatic Sensitivity Boost ASB (see Table 4.11a for settings)
ASB (=Automatic Sensitivity Boost). ASB is required in order to be able to recognise trailer drawbars after activation.
4.6
Frequency (see Table 4.11a for settings)
Four different frequencies F1, F2, F3, F4* can be set in order to avoid interference when using several loop detectors.
4.7
Direction logic (see Table 4.11a for settings)
The direction logic function can only be used with a 2-loop device. Direction logic must have been set in the basic function (see chapter 4.2). Detection
can be performed from:
Loop 1 to loop 2
4.8
Output 2 (see Table 4.11b for settings)
In a device with 2 outputs, output 2 can be either activated or deactivated.
4.9
Protection against power failure
Note: The set parameter values are retained after a power failure, independent from the "Protection against power failure" function.
= Protection against power failure activated: The sensitivity is restricted to 1–5.
4 .9.1
Signal characteristics with protection against power failure active (Function 9 = 1)
For Activation (e.g. Barriers)
Basic function 0 = 2 Barrier systems
Output
common
nc
no
common
nc
no
For Safeguarding (e.g. Barriers)
Basic function 0 = 3 Quiescent current
Output
common
nc
no
common
nc
no
4.10
Changeover from operation to configuration mode
1- loop device
Display after start -up:
Touch the «Mode» button once
1
to change to configuration
mode
2- loop device
Display after start-up:
Touch the «Mode» button once
1
2
to change to configuration
mode
A malfunction causes
the output relay to pick
2. Barrier
up. The alarm relay
drops out.
and time factor (see Table 4.11a for settings)
On delay:
The relay picks up after the
Loop
time t when the loop is acti-
Relay
vated and drops out when
the loop is exited.
Impulse by leaving the loop:
Loop
By leaving the loop,
the relay picks up after
Relay
t t
the time t, relay drops out.
From loop 2 to loop 1
(see Table 4.11a for settings)
Without power
Initialisation
Without power
Initialisation
A malfunction causes
3. Quiescent
the output relay to be
released. The alarm
current
relay drops out.
Loop
t t
Relay
Loop
Relay
t t
= Lowest sensitivity,
from both directions
Free
Free
Mode
1
Sim1
Mode
1
Loop 1 is
Sim1
selected
A malfunction causes
4. Direction logic
the output relays to be
(2-loop device
released. The alarm
only)
relay drops out.
Off delay:
The relay picks up when the
loop is activated and drops
out after the time t when the
loop is exited.
M ax. presence:
he relay picks up when the
loop is activated and drops
out again after leaving, but
at least after the time t.
= Highest sensitivity,
Occupied
Occupied
Mode
2
Loop 2 is
Sim1
selected
*factory settings
Loop
Relay
t t
Loop
Relay
t t
Free
Free