Wall-mounted Model
• Tighten the valve directly onto the fittings recessed
in the wall using the 1/2" supply tail.
• Connect the water supply and operate the valve several times
to stabilise the time flow.
Wall-mounted Exposed Models (excluding ref. 747801)
• Mount the valve on the wall using the screw/screws provided
(use rawl plugs that are suitable for the type of wall).
• Connect the water supply and operate the valve several times
to stabilise the time flow.
Wall-mounted Exposed Shower Kit (ref. 747801) (Fig. H)
• Fix the shower head e so that the nozzle f is 2.10m
from the floor.
• Assemble the column g and the valve i.
• Insert the column into the hole beneath the shower head e.
Fix the shower head e onto the wall (use rawl plugs
that are suitable for the type of wall).
• Position the collar h in the middle of the column to cover
the joint. Fix the collar h and the valve i to the wall (use rawl
plugs that are suitable for the type of wall).
• Connect to the water supply and ensure that all the connections
are watertight. Operate the valve several times to stabilise
the time flow.
Panel-mounted Models (Fig. E)
• Drill a Ø 36mm diameter hole.
• Pass the valve through the panel.
• Tighten the nut b against the panel.
• Tighten the 2 screws a using a 3mm Allen key.
• Connect the water supply and operate the valve several times
to stabilise the time flow.
Recessed Model (Fig. F)
• The wall mounting area should measure: 90x90mm,
with an adjustable depth of 50-60mm.