• Connect the valve to the water supply.
• Mount the wall plate against the wall and position the silicone
seal behind the wall plate to provide a waterproof seal between
the wall plate and the wall. Leave a drainage point to allow
any residual water to drain away.
• Fix the wall plate c in place.
• Tighten using the nut b.
• Activate the valve several times to stabilise the temperature.
THE INSTALLER MUST ENSURE THAT:
• THE SEAL AROUND THE RECESSING HOUSING IS
WATERPROOF TO PREVENT ANY INGRESS OF WATER;
• ANY WATER ACCIDENTALLY ENTERING THE RECESSING
HOUSING (E.G. CONDENSATION, RUN OFF, LEAKS, ETC.)
HAS A DRAINAGE POINT TO PREVENT ANY STAGNATION;
• THE INTEGRITY OF THE SEALS BETWEEN THE STAINLESS
STEEL WALL PLATE AND THE WALL OR THE WALL PLATE
AND THE MIXER/TAP/VALVE AT LEAST ONCE A YEAR,
AND MAKE GOOD IF NECESSARY.
If this advice is not followed, water may leak into the wall.
DELABIE cannot be held responsible for any ingress.
FOR FURTHER INFORMATION PLEASE CALL DELABIE
TECHNICAL SUPPORT UK: 01491 821821.
ALL OTHER MARKETS: +33 (0)3 22 60 22 74.
REMEMBER
• Our mixers/taps/valves must be installed by
professional installers in accordance with current regulations
and recommendations in your country, and the specifications
of the fluid engineer.
• Sizing the pipes correctly will avoid problems of flow rate,
pressure loss and water hammer (see calculation table in our
brochure and online at www.delabie.com).
• Protect the installation with filters, water hammer absorbers
and pressure reducers to reduce the frequency of maintenance
(recommended pressure from 1 to 5 bar maximum).