• Install stopcocks close to the mixer/tap/valve to facilitate
maintenance.
• The pipework, filters, non-return valves, stopcocks, bib taps,
cartridge and all sanitary fittings should be checked at least
once a year, and more frequently if necessary.
ADJUSTING THE FLOW RATE (Fig. I and J)
The flow rate is set at the factory at 3 lpm for washbasins,
6 or 9 lpm for showers (refs fitted with ROUND, TONIC JET
or GYM shower heads are set at 6 lpm) and 9 lpm for urinals.
• Remove the grub screw j using a 2.5mm Allen key.
• Remove the push-button k.
• Unscrew the cartridge l using a 28mm spanner.
• Remove the O ring o underneath the flow rate regulator n.
• Remove the regulator n sliding it off the bottom of the cartridge,
then align the marker m on the cartridge with the desired notch
on the flow rate regulator n:
- Notch 1: maximum flow rate
- Notch 6: minimum flow rate.
TEMPERATURE LIMITATION (mixers) (Fig.G)
The mixer is delivered with the temperature limiter engaged.
To remove the limiter:
• Isolate the water supply.
• Loosen the grub screw at the back of the mixer body
using a 4mm Allen key and remove the temperature selector.
• To remove the coloured limiter d, prise upwards
with a flat-headed screwdriver.
MAINTENANCE
Foreign bodies in the pipework can cause the mechanism
to malfunction.
To remove the mechanism (Fig. I):
• Remove the grub screw j using a 2.5mm Allen key.
• Remove the push-button k.