Télécharger Imprimer la page

Delabie TEMPOSOFT Mode D'emploi page 12

Robinetterie temporisée à déclenchement souple

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1
• To remove the mechanism, unscrew the cartridge l by one turn
using a 28mm spanner, then shut-off the water supply.
Continue to unscrew the cartridge l.
Automatic shut-off takes too long or there is continuous
flow (Fig. K)
• Clean the inside of the delay case t using a clean, dry cloth;
and clean the calibrated groove s with a non-metallic,
sharp point.
• Check that the lip seal q and seat r are in good condition.
• Remember to replace the spring p.
Dripping or a constant trickle (Fig. K)
• Clean the seat r or replace if damaged.
• Remember to replace the spring p.
Beware: do not grease the inside of the mechanism.
MAINTENANCE & CLEANING
Cleaning chrome and stainless steel: do not use abrasive,
chlorine or any other acid-based cleaning products.
Clean with mild soapy water using a cloth or a sponge.
Frost protection: drain the pipes and operate the mixer/tap/valve
several times to drain any remaining water. In the event of prolonged
exposure to frost, we recommend taking the mechanisms apart
and storing them indoors.
For the UK market only: Tel. 01491 821 821 - email: technical@delabie.co.uk
The installation guide is available on: www.delabie.co.uk
For all other markets: Tel. +33 (0)3 22 60 22 74 - email: sav@delabie.fr
The installation guide is available on: www.delabie.com
After Sales Care Support:

Publicité

loading

Ce manuel est également adapté pour:

Temposoft 2