9.2. T
IG BOND PADS INSTALLATION
The Tig Bond (33) pads are made of a special materials resistant to the acids and high temperatures.
For the installation, put the pad (33) over the insert (32). Fix the pad (33) with the appropriate O-ring (37).
9.3. E
LECTROLYTIC SOLUTIONS INSTALLATION
Pay attention: use adequate protective devices such as gloves and goggles
(Paragraph 2).
Pay attention: verify that you are using the electrolytic solution correct for the desired operation:
Neutral Bomar (31a) weld-cleaning solution
Tig Bomar (31b)
Brill Bomar (31c)
1.
Unscrew the tube tank cup (31) and remove the protection film.
2.
Do not to turn the tube (31) over. Connect it to the torch (28) and fix it by screwing the ring nut.
9.4. W
-
ORK
PROCESS SELECTION
After following the instructions for electrical installing (see paragraph 6):
1.
Turn the TIG/MIG switch (7) on the function MIG.
2.
Turn the CLEANING/POLISHING switch (6) on the function you selected:
CLEANING: weld-cleaning function.
POLISHING: surface - polishing function.
Right use:
Graphite insert (32)
Cleaning
Graphite insert (32)
Brush (34) ............................................................
Brush (34) ............................................................
Graphite insert (32)
Polishing
Brush (34) ............................................................
Notes: the brush is ideal to work the corners and the areas that are difficult to clean/polish with inserts and pads.
weld-cleaning solution
weld-polishing solution
+ Tig Bond pad (33)
+ Tig Bond pad (33)
+ Tig Bond pad (33)
38
Safety Regulations
+ Neutral Bomar solution (31a)
+ Tig Bomar solution (31b)
+ Neutral Bomar solution (31a)
+ Tig Bomar solution (31b)
+ Brill Bomar solution (31c)
+ Brill Bomar solution (31c)