2.2 TYPICAL INSTALLATION
D
C
A
B
KEY
A OPERATOR
B OPENING PHOTOCELLS
C CLOSING PHOTOCELLS
D FLASHING LIGHT
E KEY SELECTOR SWITCH
F CENTRAL CLOSING STOP
3 TECHNICAL SPECIFICATIONS
CONDOR 220
Power supply
Operator power supply
24V
ONE 24V
Power consumption
110 W
Current input
5 A
Torque
150 Nm
Duty cycle
30%
Protection rating
Insulation class
I I
Working temperature
Speed
Weight
10 Kg
LIMITS OF USE - CONDOR 220
LEAF WEIGHT (Kg)
LIMITS OF USE - CONDOR 350
3.5
3.25
3
2.75
2.5
2
1.5
0
25
50
75 100 125 150 175 200 225 250 275 300 325 350 375
LEAF WEIGHT (Kg)
E
C
A
F
B
CONDOR 350
230V ~ 50 Hz
230V ~
24V
ONE 24V
280 W
150 W
1,2 A
6,5 A
250 Nm
200 Nm
Intensive use
IP 44
1 earth
I I
from -20°C to + 50°C
0,10 rad/s
10 Kg
10 Kg
4 INSTALLATION
4.1 PRELIMINARY CHECKS
Ensure that all material used is in perfect condition and fit for purpose.
• Make sure that the mechanical structure of the gate is suitable for automation.
This product cannot be used to automate a gate unless the gate is already in
good working order and safe and it cannot remedy defects caused by incorrect
installation or lack of maintenance of the gate.
• Check the stated operating limits.
• Move the gate leaves manually in both directions to ensure the force required is
constant throughout the full range of movement.
• Move the gate leaves manually to any position then release them to check that
they remain stationary.
• Check that the area in which the operator is to be mounted is compatible
with the size of the unit and make sure there is sufficient clearance for the full
movement of the arm.
• Ensure that there is sufficient space around the operator to perform the manual
release procedure.
• Ensure that the surfaces on which the devices are to be mounted are solid and
able to provide a secure anchorage.
• Ensure that all devices to be installed are in a protected location and such as to
minimize the risk of accidental impact.
4.2 OPERATING LIMITS
Before starting the installation work make sure the operator is correctly sized
in relation to the dimensions and length of the gate leaves and within the
limits of the values given in the chapter "Product technical specifications":
For installation purposes the minimum width of the gate pillar is 200mm.
The operator arm must be secured to the gate leaf in a sufficiently robust
position (e.g. on the gate frame).
4.3 PREPARATORY WORK FOR INSTALLATION
(FITTING THE ARTICULATED ARMS)
• Release the operator (see heading 4.4.3)
• Assemble arm 1 and arm 2 (FIG. 3)
• Fix the arms to the drive shaft (FIG. 4)
• Fit the cover and secure it with the two screws supplied (FIG. 5). The
sole difference between the LH and RH leaves lies in the position of arm 2.
4.4 INSTALLATION
4.4.1 INSTALLATION
• With reference to FIG. 1 measure distance D and, depending on the required
opening angle, you can obtain dimensions B and A.
• Check that the arm has sufficient operating clearance to complete the opening
movements (dimensions C and E). (FIG. 1).
• Referring to fig. 6, drill 4 holes of suitable diameter in relation to the type of
anchor bolts used to fix plate P.
• Comply with the minimum dimension of 150 mm required to avoid installing the
operator too close to the ground. (FIG. 6).
• Drill 2 holes for fixing the articulated bracket S, complying with the value
of dimension A (FIG. 1) and ensuring alignment (dimension 60 mm) with the
operator bracket P shown in (FIG. 6).
• If the areas of fixing are too insubstantial or insufficiently sturdy, they must be
reinforced.
• Bring the gate leaf to the fully closed position (FIG. 7).
• Remove the operator cover by unscrewing the 2 lateral screws elimina and the
central screw located under the release lever (FIG. 8).
• Fix the operator to the bracket with the two nuts and bolts supplied; (FIG. 9).
• Fix the arm to the articulated bracket using bushing, washer, nut and bolt (FIG. 10).
• Check that the bracket and arm are perfectly level.
• With the operator released, open the gate leaves completely and check the
operating clearances of the two arms.
• Adjust the limit stop as described in heading 4.4.2.
4.4.2 INSTALLATION OF LIMIT STOPS AND SWITCHES
Mechanical limit stop
The operator is equipped with two adjustable mechanical limit stops that
arrest the gate when the fully open and fully closed positions are reached.
• With the operator released, bring the gate leaf to the desired opening position
(FIG.11).
• Fix the mechanical limit stop fully home against arm 1 and secure it with the
supplied screw (FIG. 12).
• The toothed profile of the limit stops and the lower surface make it possible to
adjust the position in 5° steps.
• Perform the same procedure with the gate leaf in its fully closed position (FIG. 13).
COMUNELLO ®Copyright 2021 - All rights reserved
19