Key Automation 14A Instructions Et Avertissements Pour L'installation Et L'usage page 28

Logique de commande modulaire pour un ou deux moteurs 24 vcc
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 34
EN
PARAMETERS
SLOW DOWN
7
CLOSING SPEED
SLOW DOWN
7
CLOSING SPEED
FASTLINE
8
STEP BY STEP
MOTOR 2
9
DELAY
MOTOR 2
DELAY
9
FASTLINE
(swing gate only)
SLOW DOWN
10
LENGTH
SLOW DOWN
10
LENGTH
FASTLINE
11
ENERGY SAVING
12
BLACK OUT
* For SUN4024 sliding gate motors the parameter will be DEFAULT 1 - MIN 1 - MAX 2
** For SUN4024 sliding gate motors the parameter will be DEFAULT 15 - MIN 15 - MAX 100
28
DESCRIPTION
Motor speed during closing deceleration phase.
1 = minimum
2 = low
3 = medium
4 = high
5 = maximum
Motor speed during closing deceleration phase.
1 = minimum
2 = low
3 = medium
SBS configuration:
0 = Normal (OP-ST-CL-ST-OP-ST...)
1 = Alternate STOP (OP-ST-CL-OP-ST-CL...)
2 = Alternate (OP-CL-OP-CL...)
3 = Apartment block – timer (always opens)
4 = Apartment block with immediate reclosure
(always opens. Closes if gate is open)
Leaf 2 opening delay with gate closed
0 - 60 sec.
Leaf 2 opening delay with gate closed 0 - 60
sec.
Deceleration distance
0 = Customised decelerations
1 to 100 = Motor deceleration percentage
during opening and closure. With KUBE,
programmable deceleration during opening and
closure will be individually adjustable for each
engine
Deceleration distance
20 to 100 = Motor deceleration percentage
during opening and closure
Energy saving: enables photocell switch-off
when gate is closed
0= disabled
1= enabled
0 = OFF
1 = When the power line is restored, the motor
will automatically re-close
DEFAULT
MIN.
1 *
1
1
1
0
0
2
0
2
0
20 **
0
20
5
0
0
0
0
MAX.
UNIT
5
3
4
60
s
60
s
% (step
100
of 1)
100
% (step of 1)
1
1

Hide quick links: