Configuration - WIKA CPH62I0 Mode D'emploi

Indicateur de pression portable
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

6. Commissioning, operation
Menu
Param.
´MENU´
GB
SEt
Set Alarm: Alarm function configuration
AL.
AL.
[1,2,DIF]
AL.Lo
[1,2,DIF]
AL.Hi
[1,2,DIF]
SEt
Set Logger: Logger function configuration
LoGG
Func
CYCL
Lo.Po
SEt
Set Clock: Setting of real time clock
CLOC
CLOC
dAtE
YEAr

6.3 Configuration

To change device settings, press the ´SET/MENU´ key for 2 seconds. This will access
the configuration menu (main display: ´SEt´).
Pressing the ´SET/MENU´ key again scrolls down the menus, pressing the ´TARA´
key scrolls across to the associated parameters, which can then be selected with the
´TARA´ key.
The parameters can be altered using the ´MIN´ or ´MAX´ keys. Pressing the ´SET/
MENU´ key again saves the settings and returns you to the main configuration menu.
The ´STORE/QUIT´ key exits the configuration and returns you to standard measuring
mode.
22
Setting
Meaning
or
on
Alarm function on
no. So
Alarm function on
oFF
No alarm function
Min-Range ...
Min alarm limit
... AL.Hi
(not when AL.oFF, Min-Range is the lower display range of the
connected sensor)
AL.Lo ...
Max alarm limit
... Max-Range
(not when AL.oFF, Max-Range is the upper display range of the
connected sensor)
CYCL
Cyclic: logger function 'cyclic logger'
Stor
Store: logger function 'discrete value logger'
oFF
No logger function
1 ... 3600
Cycle time for cyclic logger [seconds]
on / oFF
Low-power logger with very low power consumption (only if cyclic
logger with slow measuring rate)
HH:MM
Clock: set time hours:minutes
TT.MM
Date: set time day.month
YYYY
Year: set time year
* If there is existing data in the logger memory, the menus/param-
eters cannot be accessed! If these need to be adjusted, the logger
memory must first be cleared! (see chapter "6.4 Operation of
logger".)
** This menu can only be invoked if an appropriate sensor is connect-
ed to connection 1. When using a second sensor on connection 2
then settings are adopted.
WIKA operating instructions, model CPH62I0
*
*
*
*