The Manufacturer:
AUTOMATISMI BENINCÀ SPA
Address:
Via Capitello, 45 - 36066 Sandrigo (VI) - Italy
Declares that the product:
Control box for 1 24V DC motor, ideal for tilt-up doors:
LOGICA24.RI
conforms with the requirements of the following EU Directives:
• DIRECTIVE 2004/108/CE OF THE EUROPEAN PARLIAMENT AND COUNCIL, 15 December 2004, in relation to the harmonisation of the legisla-
tion of member states regarding electromagnetic compatibility , in abrogation of Directive 89/336/CEE, per the following harmonised standards:
EN 61000-6-2:2005, EN 61000-6-3:2007.
• DIRECTIVE 2006/95/CE OF THE EUROPEAN PARLIAMENT AND COUNCIL, 12 December 2006, in relation to the harmonisation of the legisla-
tion of member states regarding electrical material intended to be used within certain voltage ranges, per the following harmonised standards:
EN 60335-1:2002 + A1:2004 + A11:2004 + A12:2006 + A2:2006 + A13:2008; EN 60335-1-103:2003.
as applicable:
• DIRECTIVE 1999/5/CE OF THE EUROPEAN PARLIAMENT AND COUNCIL, 9 March 1999 in relation to radio equipment and telecommunications
terminals and the mutual recognition of their conformity, per the following harmonised standards:
ETSI EN 301 489-3 V1.4.1 (2002) + ETSI EN 301 489-1 V1.4.1 (2002) + ETSI EN 300 220-3 V1.1.1
(2000) + EN 60950-1 (2001)
Benincà Luigi, Legal representative.
Sandrigo, 02/11/2010.
The electronic control unit Logica24 RI can be used to control 1 or 2 motors with a power not exceeding 120W+120W.
IMPORTANT: Should two motors be used, connect the limit switches of one single motor to the control unit.
a) The wire connections and the operating logic should be in compliance with regulations in force.
b) The cables featuring different voltage should be detached, or adequately insulated by an additional insulation of at least 1 mm.
c) The cables should be further fastened in proximity to the terminals.
d) Check all connections before powering the unit.
e) Check that setting of the Dip-Switches are the required ones.
f) Normally Closed inputs which are not in use should be short-circuited 230VAC – keep to phase/neutral).
Terminal
Function
No.
1-2
Power supply
3-4
Flashing light
5-6
Light, Motor 2
7
COM
8
SWO
9
SWC
10
STOP
11
PHOT
12
OPEN
13
CLOSE
14
Step-by-Step
15-16
Motor 1
17-18
Motor 2
CE Declaration of Conformity
Declaration in accordance with Directives 2004/108/CE (EMC); 2006/95/CE (LVD)
Logica24 RI Control unit
INPUT/OUTPUT FUNCTIONS
Logica24 RI Control Unit
Description
Input, 230VAC 50Hz (1-Phase/2-Neutral)
Connection of flashing light, 24Vac 40W max.
Connection to the courtesy light of motor 2
(only when 2 motors are in use)
Common for limit switch and all control inputs.
Input, OPEN limit switch (N.C. contact)
Input, CLOSE limit switch (N.C. contact)
Input, STOP push button (N.C. contact)
Input, connection to safety devices, N.C. contact
(e.g. Photocells)
Input, OPEN push button (N.O. contact)
Input, CLOSE push button (N.O. contact)
Input, step-by-step push button (N.O. contact)
Connection to motor 1 (15+/16-)
Connection to motor 2 (15+/16-)
To be used only when 2 motors are in use
GENERAL WARNINGS