11. LEAK TESTING
Serious burns to the skin or damage to property.
Do not use an open flame to check for leaks.
Leak testing before start-up, check the product connections for leaks.
1. Close all shut-off fittings on the gas appliance.
2. Slowly open the gas vapour or the gas cylinder valve(s).
3. Spray all connections with a foam producing substance according to EN 14291
(e.g. leak spray, item no. 02 601 00).
4. Bubbles will form in the foam producing substance if there are any leaks.
you cannot stop the leaks, you must not use the product.
Observe the applicable national installation regulations for LPG systems.
12. START-UP
After the product has been ASSEMBLED and LEAK TESTING has been carried out
successfully, it is immediately ready for operation.
13. OPERATION
• Use this product only when you have carefully read the assembly and operating
manual.
• For your own safety, observe all the safety messages in this assembly and operating
manual.
• Please also consider the safety of others.
Open or close the valve by turning the handwheel as far as it will go in the
arrow direction OPEN "+" or CLOSED "–".
14. MAINTENANCE
Upon proper ASSEMBLY and OPERATION, the product is maintenance-free.
Ammonia, contained in some soaps and cleaning agents, corrodes fittings.
After a couple of months, fittings that have made contact with ammonia may show
cracks or leakages.
Ammonia-containing soap and cleaning agents may not be used for this product!
15. SHUT-DOWN
Risk of burning or fire.
If more bubbles form, re-tighten the connections (see ASSEMBLY). If
Close all free connections in the feed lines of the LPG
system with suitable caps
Remove the cylinder valve when you are transporting
and storing the propane cylinder, close the sealing nut
propane cylinder tightly.
to prevent gas flowing out!