4) Move SW1 to "PRGM" on Program Module.
5) Turn on the power. The sensor LEDs will sequentially
flash through the power up test pattern.
6) The sensor LEDs will light up the last valid
configuration.
7) Each time SW2 is pressed on the Program Module, the
sensor LEDs will shift to the next valid configuration.
This sequence is Top #1 to Top #8 and then Top and
bottom #1 to Top and Bottom #8. This sequence will
repeat every time the pushbutton is pressed.
8) Press SW2 until the pattern representing the number of
connected sensors on the trailer is correct. Move SW1
to the "RUN" position. The monitor will flash the
sensor LEDs sequentially through the test pattern.
9) If all connected sensors are dry there shouldn‟t be any
RED compartment lights on. At this point, if the AUX
LED is on the PERMIT LED should also be on.
10) Remove power from the monitor. Remove the
programming module, reconnect the timer reset switch
and turn power back on to the monitor.

Operation

Normal Operation

When power is applied to the FT203P monitor, the unit will
sequentially flash the sensor LEDs through the power up test
pattern. This sequence is from the TOP #1 LED to the TOP #6
LED then from the BOT #1 LED to the BOT #6 LED. Once
this sequence is completed, the unit tests all the sensor inputs.
A PERMIT signal will be issued if:
 All the sensor inputs that have been programmed as see
active "dry" sensor signals.
 Any of the Retain sensors are wet and the Timer/Reset
pushbutton has been pressed.