Output Connection Procedure; Parallel Installation - ESAB ESP-600C Manuel D'instruction

Masquer les pouces Voir aussi pour ESP-600C:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 186
sectIon 3

3.5.2 output connection procedure

1. Remove access panel on the lower front of the power source.
2. Thread output cables through the openings at the bottom of the front panel or at the bottom of the power source im-
mediately behind the front panel.
3. Connect cables to designated terminals mounted inside the power source using UL listed pressure wire connectors.
4. Replace panel removed during the first step.

3.6 parallel Installation

Two ESP-600C power sources may be connected together in parallel to extend the output current range.
cautIon
Access Panel
parallel power source minimum output current exceeds recommend-
ed amounts when cutting below 100a.
use only one power source for cutting below 100a.
We recommend disconnecting the negative lead from the supple-
mental power source when changing to currents below 100a. this
lead should be safely terminated to protect against electric shock.
107
InstallatIon

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

055800646705580064680558006469

Table des Matières