sectIon 3
3.4.2 Input conductors
•
Customer supplied
•
May consist either of heavy rubber covered copper conductors (three power and one ground) or run
in solid or flexible conduit.
•
Sized according to the chart.
notIce
3.4.3 Input connection procedure
3
1 = primary terminals
2 = chassis ground
3 = power Input cable access opening (rear panel)
Input conductors must be terminated with ring terminals.
Input conductors must be terminated with ring terminals sized for
12.7 mm (0.50") hardware before being attached to the esp-600c.
1
2
1. Remove left side panel of the ESP-600C
2. Thread cables through the access opening in the rear panel.
3. Secure cables with a strain relief or conduit coupling (not sup-
plied) at the access opening.
4. Connect the ground lead to the stud on the chassis base.
5. Connect the power lead ring terminals to the primary termi-
nals with supplied bolts, washers and nuts.
6. Connect the input conductors to the line (wall) disconnect.
105
InstallatIon