Filling the dismounted coolant container
Fig. 5
Upper closing cap
(figure 5)
Pull the empty coolant container out of the
2.
drill stand housing of the magnetic core drill.
Unscrew the cap from the coolant container.
Fill in pump-feedable cooling lubricant,
e.g. Slugger cutting oil.
1.
Screw the cap onto the coolant container
again.
Insert the filled coolant container into the
holder on the drill stand housing intended for
this purpose.
Coolant container
3.
4.
5.