Energy Saving System; Storage; Installation; Commissioning - Storm SAEP Manuel D'utilisation Et D'entretien

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 63

2.8 Energy Saving System

The machine is equipped with software that manages the
automatic standby system during breaks, the night energy-
saving feature and the smart temperature adjustment.
This allows a considerable amount of energy to be saved dur-
ing night breaks, whilst maintaining the machine in a condi-
tion that can quickly return to operating mode.
Moreover, the software only distributes the power where and
when needed, thus allowing energy to also be saved during
normal operation.
When programmed, the system automatically puts one or
more groups into standby mode when the workload decreas-
es and prepares them for full capacity when needed.
Three choices are provided:
: manual standby activation,
: programmed operation,
: self-learning management.
To activate the Energy Saving mode, see para. 6.10
on page 49.

3. STORAGE

The machine is stored by the Manufacturer or Technician.

4. INSTALLATION

The machine must only be installed by the Technician.
When the machine is being installed, the Techni-
cian must replace the water in the hydraulic cir-
cuits.
The machine's support base must be perfectly flat,
not incline by more than 2° and have no irregulari-
ties.
The electrical system must be equipped with a
suitable residual-current device in compliance with
current laws and safety regulations.

5. COMMISSIONING

The machine must only be commissioned by the Technician.
44
216
of

6. OPERATION

6.1 Safety precautions

Carefully read the instructions provided in chapter
"I. SAFETY PRECAUTIONS" on page 33.

6.2 Emissions

Vibrations
In operating conditions that comply with the indications of
correct use provided in this manual, any detected vibrations
do not give rise to dangerous situations.
Sound emissions
The noise level emitted by the machine is on average lower
than 70 dB; therefore, the use of personal protective equip-
ment to prevent hearing damage is not compulsory.
If the machine emits any unusual sounds, the Technician
must be notified.
Electromagnetic environment
The machine is designed to work properly in any industrial
electromagnetic environment, falling within the Emission and
Immunity limits provided by current standards.

6.3 Turning the machine on and off

Before using the machine, carry out some empty
dispensing cycles with the filter holders attached
for several seconds. This procedure releases any air
inside the hydraulic circuit and in turn, allows the dispensing
groups to fully heat up.
If the machine is inactive for longer than a week,
the Technician must replace 100% of the water in-
side the hydraulic circuits.
After the hydraulic and electrical mains have been connected
by a Technician, make sure that the drain tray under the cup
holder grille (10) is correctly connected to the drain.
10