INSTALLATION
WARNING!
combustible surface, nor can it be located below a combustible overhang.
The glass embers and the burner assembly are shipped together.
Remove the glass embers and burner assembly and check for damage. DO NOT install damaged components.
The glass embers may have sharp edges, wear safety glasses and gloves when handling.
Place the appliance on a level/secure surface in desired location. This location must be adjacent to the
gas supply line or cylinder.
NOTE: Minimum clearances to combustible construction must be maintained, see "SPECIFICATIONS" section.
WARNING!
and connected to the gas supply in order to safely turn off the burner.
THE ON/OFF GAS VALVE IS USED TO TURN THE BURNER ON AND OFF.
NATURAL GAS
Connect the incoming gas supply line to the on/off gas valve of the appliance. Make certain ALL gas connections are
tight, turn the on/off valve at the unit slowly to the on position and use soapy water to test for leaks as indicated in
the diagrams.
DO NOT USE AN OPEN FLAME.
Manual Gas
Valve (on/off)
LP (PROPANE) GAS
Attach cylinder retaining bracket supplied to the base of the cylinder. Then secure to the surface to which it
sits. Cylinder should be on a level surface.
This appliance has been designed for use with a 20lb. (9.1kg) or a 30lb (13.6kg) size propane cylinder only
(not supplied).
Make sure cylinder valve is in its full off position. (Turn clockwise to stop).
Check cylinder valve features to ensure it has proper external mating threads. (Cylinder Valve Marked:
USE WITH TYPE 1)
Inspect hose shipped with the unit for damage. Never attempt to use damaged or plugged equipment. See
your local LP Gas Dealer for repairs.
After inspecting the LP hose shipped with the unit, connect the end with the female fitting on the hose to
the male fitting on the on/off gas valve at the end of the flex tube. Tighten fittings using 2 wrenches.
When connecting regulator assembly to the cylinder valve, hand tighten black QCC1 nut clockwise to a
positive stop. DO NOT use a wrench to tighten. Use of a wrench may damage the quick closing coupling
nut and result in a hazardous condition.
Locate the hose out of pathways where people may trip over it or in areas where the hose may be subject
to accidental damage.
Open cylinder valve fully (counter-clockwise). Turn the on/off valve at the unit slowly to the on position
and use a soapy water solution to check all connections for leaks as indicated in the diagrams before
attempting to light the appliance. If a leak is found, turn tank valve off and do not use the appliance until
repairs can be made.
DO NOT USE AN OPEN FLAME.
Cylinder Retaining
www.napoleonfireplaces.com
When the appliance is being used with the optional tripod, it must not be situated on a
You must have clear and easy access to the on/off valve AFTER the appliance is installed
Burner Assembly
Burner Assembly
Manual Gas
Valve (on/off)
Bracket

Publicité

loading

Ce manuel est également adapté pour:

Patioflame gpfgp