Télécharger Imprimer la page

Connecting To Power Supply - Stihl HSE 42 Notice D'emploi

Masquer les pouces Voir aussi pour HSE 42:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

English
3.4.2
Horizontal Cut
Hold the cutter bar at an angle of 0° to 10° as
you swing the hedge trimmer horizontally.
Swing the cutting blade in an arc towards the
outside of the hedge so that the cuttings are
swept to the ground.
Repeat the procedure several times on wide
hedges.
4
Connecting to Power Sup‐
ply
The voltage and frequency of the machine (see
rating plate) must match the voltage and fre‐
quency of the power connection.
The minimum fuse protection of the power con‐
nection must comply with the specifications – see
"Specifications".
22

4 Connecting to Power Supply

The machine must be connected to the power
supply via an earth-leakage circuit breaker to dis‐
connect the power supply if the differential cur‐
rent to earth exceeds 30 mA.
The power connection must correspond to
IEC 60364 and relevant national regulations.
4.1
Extension cord
The design of the extension cord must at least
fulfill the same features as the connecting cord
on the machine. Observe the design marking
(type designation) on the connecting cord.
The cores in the cord must have the following
minimum cross-section depending on the mains
voltage and cord length.
Cord length
220 V – 240 V:
Up to 20 m
20 m to 50 m
100 V – 127 V:
Up to 10 m
10 m to 30 m
► Insert the plug (1) into the extension cord cou‐
pling (2).
Minimum cross-section
2
1.5 mm
2
2.5 mm
AWG 14 / 2.0 mm
AWG 12 / 3.5 mm
1 2
0458-762-9621-B
2
2

Publicité

loading

Ce manuel est également adapté pour:

Hse 52