SPECIFICATIONS
Electrical
Installation must comply with all applicable electrical codes
and be properly grounded (earthed).
Locate the electrical supply as shown in the illustrations on
pages 3–4. A separate circuit, servicing only this appliance
is required. A ground fault circuit interrupter (GFCI) is not
recommended and may cause interruption of operation.
Performance may be compromised if the electrical supply is
less than 220 volts.
When multiple cooktops are installed side by side, each unit
must have its own separate recommended electrical circuit.
REQUIRED POWER SUPPLY
INDUCTION / ELECTRIC
Single phase
220-240V AC, 50/60 Hz
3phase
380-415V AC, 50 Hz
MAXIMUM CONNECTED LOAD
INDUCTION COOKTOPS
SINGLE PHASE
381 mm
3.7 kW
610 mm
6.85 kW
762 mm
7.4 kW
914 mm
11.1 kW
ELECTRIC COOKTOPS
SINGLE PHASE
381 mm
2.9– 3.4 kW
2.9– 3.4 kW
762 mm
6.2– 7.5 kW
3.3 – 3.9 kW
914 mm
8.9 –10.5 kW
3.4– 4.0 kW
Refer to the wiring diagram showing the connections for
each lead to the terminal box on the unit.
WARNING
The complete appliance must be properly grounded at
all times when electrical power is applied.
Do not ground appliance with the neutral (white) house
supply wire. A separate ground wire must be utilized.
If aluminum house supply wiring is utilized, splice the
appliance copper wire to the aluminum house wiring
using special connectors design and agency certified
for joining copper and aluminum. Follow the connector
manufacturer's recommended procedure carefully.
Improper connection can result in a fire hazard.
IMPORTANT NOTE:
Connection of this appliance should be
through a fused connection unit or a suitable isolator, which
complies with national and local safety regulations. The
3PHASE
on/off switch should be easily accessible after the appli-
3.7 kW
ance has been installed. If the switch is not accessible after
3.7 kW
installation (depending on country) an additional means of
3.7 kW
disconnection must be provided for all poles of the power
3.7 kW
supply. When switched off there must be an all pole contact
3PHASE
gap of 3 mm in the isolator switch. This 3 mm contact dis-
connect gap must apply to any isolator switch, fuses and/or
relays according to EN60335.
˜
3N
L1
L1
L2
L3
N
Single phase wiring diagram.
3phase wiring diagram.
381 mm Cooktop

STANDARD INSTALLATION

330 mm
˜
SIDE VIEW
NOTE: Shaded area above countertop indicates minimum clearance to combustible surfaces,
N
combustible materials cannot be located within this area.
64 mm
343 mm
495 mm
64 mm
COUNTERTOP CUT-OUT
457 mm
762 mm
51
mm
E
914 mm
min
FLOOR TO
COUNTERTOP
FRONT VIEW
|
wolfappliance.com
3