24/96
Bosch Rexroth AG
XDAc2 interface (male)
This interface is intended for connecting an
NKLx network cable in order to integrate
further participants.
1
6
Fig. 3: 9-pin Sub-D plug
Table 3
Pin Signal Description/
function
1
GNDiso Bus reference
potential, isolated to
PE
2
-
-
3
AC2+
Data bus, positive
differential cable
4
AC1+
Control bus, positive
differential cable
5
GNDiso Bus reference
potential, isolated to
PE
6
-
-
7
VEEiso
Supply bus, isolated
to PE
8
AC2–
Data bus, negative
differential cable
9
AC1–
Control bus, negative
differential cable
5
9
Voltage/
current/
standard
0 V,
potential-
free
-
RS485,
differential
RS485,
differential
0 V,
potential-
free
-
10 V-25 V,
potential-
free
RS485,
differential
RS485,
differential
NK350 / NK350S | 3 609 929 B69/2008-11