Swegon NIVEAU 3 Manuel De L'utilisateur page 27

Table des Matières

Publicité

CONDUCTOR
ModBus Register W1
Input Status
Discrete Input (1 bit)
Modbus
Name
1x0036
No parameters
1x0037
Parameter missing
1x0038
Parameter value error
1x0039
Parameter file size
1x0040
Wrong parameter file
1x0041
Check Duct Group SM
1x0042
Check Duct Group DC
1x0043
Previous parameters are lost
1x0044
Factory parameters take up
1x0045
TBD
1x0046
TBD
1x0047
No supply pressure from AHU
1x0048
No exhaust pressure from AHU
1x0049
Supply duct 100% open
1x0050
Exhaust duct 100% open
1x0051
Low voltage detect
1x0052
TBD
1x0053
Duct group member missing
1x0054
Negative pressure
ModBus Register W1
Holding register
16 bit integer register
Modbus
Name
4x0001
Relay in Emergency
4x0002
Application transition
4x0003
Room number
4x0004
Valve exercise
4x0005
Motion Timer
4x0006
General warning time
4x0007
PI-overload warning time
4x0008
Set-point warning time
4x0009
Not used
4x0010
Not used
4x0011
Not used
4x0012
Not used
4x0013
Not used
4x0014
System type
4x0015
Number of Room units
4x0016
Window switch
4x0017
Occupancy switch
4x0018
Actuator Type Cool
4x0019
Actuator Type Heat
4x0020
Not used
Design déposé. Sous réserve de modifications sans préavis.
Read only
Min/Max
Remarks
0/1
ALARM, requires HW reset
0/1
ALARM, requires HW reset
0/1
ALARM, requires HW reset
0/1
ALARM, requires HW reset
0/1
ALARM, requires HW reset
0/1
ALARM, resets after right parameters
0/1
ALARM, resets after right parameters
0/1
ALARM, requires HW reset
0/1
ALARM, requires HW reset
0/1
ALARM, requires HW reset
0/1
ALARM, requires HW reset
0/1
ALARM, resets automatically
0/1
ALARM, resets automatically
0/1
ALARM, resets automatically
0/1
ALARM, resets automatically
0/1
ALARM, resets automatically
0/1
ALARM, resets automatically
0/1
ALARM, resets automatically
0/1
ALARM, resets automatically
R/W
Min/Max Remarks
0/1
0=Close, 1=Open, 2=No Action
1/8
1=Normal, 3=Manual, 4=Stand-by,
5=Emergency, 6=NightCool
0/72
Valve exercise 0=Not used (hours)
0/20
Motion timer (minutes)
0/60
Warning delay, general (minutes)
0/60
Warning delay, PI-overload (minutes)
0/60
Warning delay, Set point (minutes)
1/4
1= Heat, 2= Cool, 3= Change Over, 4=Heat+Cool
1/2
1=One room unit, 2= Two room units
0/2
0=Not used, 1=Normaly Closed, 2=Normaly Open
0/2
0=Not used, 1=Normaly Closed, 2=Normaly Open
1/2
1=24VAC, 2=0-10V
1/2
1=24VAC, 2=0-10V
20110322
Default
Default
0
48
20
30
10
10
4
1
0
0
1
1
27
www.swegon.com