Burglary alarm (magnetic contact required - for output 1 only)
• Press the buttons "7" --- "3" --- "0" --- "#"
The alarm is deactivated.
• Press the buttons "7" --- "3" --- "1" --- "#"
The alarm is triggered in case of burglary.
If a magnetic contact is connected, the function must be activated.
Factory setting = alarm signal is deactivated!
Programming the alarm time (clamp ALMOUT)
• Press the keys "7" --- "4" --- ("01" – "99" minutes) --- "#"
Now you can define the duration of the alarm (01 to 99 minutes)
Factory setting = alarm time: 1 minute
10.10 Programming the security functions (for output 1 only)
• Press the buttons "8" --- "0" --- "0" --- "#"
The security functions are inactive.
• Press the buttons "8" --- "0" --- "1" --- "#"
Alarm display - ALM OUT after 10 invalid ID cards or 10 wrong codes or 1 valid ID card and
5 wrong user numbers inputs.
The alarm can be turned off by reading a valid user ID card or entering the corresponding user
code or the user ID card plus user code.
• Press the keys "8" --- "1" --- (03 - 10 inputs) --- " " --- (01-99 minutes) --- "#". With this setting,
you can define when the system is to be blocked
If you enter the digit "03", the system is blocked after the 3rd invalid ID card or wrong codes.
If you enter the digit "04", after the 4th wrong entry, etc.
Either 3 -10 invalid ID cards or 3-10 wrong codes or 1 valid ID card + 5 wrong user numbers.
Then the system can be blocked for at least 1 minute and at most 99 minutes.
The system blockage can be deactivated by reading a valid user ID card or entering the
corresponding user code or the user ID card plus user number.
41