10.5 Programming the opening times / relay output (output 1)
• Press the keys "4" --- "0" --- ("01" – "99" seconds) --- "#" output 1: Relay opens between 1
and 99 seconds
• Press the buttons "4" --- "1" --- "#"
Output 1: is locked
Factory setting = short-time mode: 3 seconds!
10.6 Saving of user codes 2 (output 2)
• Please note that the following chapters only refer to saving "user number" with "user code"
for output 2!
• Enter any 3-digit numerical combination for each user code - this may not be repeated during
programming, however!
• Press the keys "5" --- "1" --- "3-digit user number" --- "4 to 8-digit user code" --- "#" (green LED
(5) blinks) --- "#" (green LED (5) no longer blinks). Input is completed. Red LED (2) is lit as
long as output 2 is active.
If you want to save several user codes, you do not have to press the "number" key "#"
after each individual entry. Save the individual entries as described above and press
the "number" key "#" after the last entry. This saves all previous entries as well.
10.7 Deleting user codes (output 2)
• Press the buttons "5" --- "0"--- "0" --- "0" --- "0" --- "#"
This deletes all user codes.
• Press the keys "5" --- "2" --- "user code" to be deleted --- "#".
Now the entered user code is deleted.
• Press the keys "5" --- "3" --- enter the "user number" of the user code --- "#".
Now the additional user code with the respective user number is deleted.
39