8. Pin assignment
a) DPC Jumper
For resetting the factory code.
b) TAMPER (sabotage contact)
Is triggered as soon as the housing cover is opened.
c) TAMPER BEEP
Set this to "ON" - internal buzzer will sound if the cover is opened.
Set this to "OFF" - internal buzzer will be disabled.
d) TAMPER H NC. L (NC contact)
Tamper output for connecting to external alarm system.
e) DOOR BELL
Connection of a door bell
f)
N.O. EG
Connection of Egress Button
g) Connection "12V DC IN + -"
Connection of the supply voltage