Operation • Service
For automatic operation, plug or wire pump into an automatic
float switch or pump controller. Pump will run continuously
when plugged directly into an electrical outlet. Connect or
wire pump to its own individual branch circuit with no other
outlets or equipment in the circuit. Size fuses or circuit breakers
according to Specifications chart.
Risk of electric shock . Can shock, burn or kill.
Be sure that power supply information (Voltage/Hertz/Phase)
on pump motor nameplate matches incoming power supply
exactly. Install pump according to all electrical codes that
apply.
Operation
NOTICE Do not allow pump to run in a dry sump. It will void
the warranty and may damage the pump.
An automatic overload protector in the motor will protect
motor from burning out due to overheating/overloading. When
motor cools down, overload protector will automatically reset
and start motor.
If overload trips frequently, check for cause. It could be a stuck
impeller, wrong/low voltage, or electrical failure in motor. If an
electrical failure in the motor is suspected, have it serviced by a
competent repairman.
Pump is permanently lubricated. No oiling or greasing
is required.
WARNING
Risk of electrical shock .
Can burn or kill.
Do not lift pump by power
cord.
For parts or assistance, call Flotec Customer Service at 1-800-365-6832.
Service
kill. Before removing pump from basin for service, always
disconnect electrical power to pump and control switch.
not lift pump by power cord. See Cord Lift Warning below.
Submerge pump in a disinfectant solution (dilute chlorine
bleach) for at least one hour before disassembling pump.
The pump motor contains a special lubricating oil which
should be kept clean and free of water at all times.
Check operation by filling sump with water and observing
pump operation through one complete cycle.
property damage. Failure to make this operational check may
lead to flooding and premature failure.
NOTICE This unit is not designed for applications involving salt
water or brine! Use with salt water or brine will void warranty.
Cord Lift Warning
Risk of electric shock . Can shock, burn or
Risk of electric shock . Can shock, burn or kill. Do
Risk of flooding . Can cause personal injury and/or
1. Attempting to lift or support pump
by power cord can damage cord and
cord connections.
2. Cord may pull apart, exposing bare
wires with possibility of fire or
electrical shock.
3. Lifting or supporting pump by power
cord will void warranty.
4. Use lifting ring or handle on top
of pump for all lifting/lowering of
pump. Disconnect power to pump
before doing any work on pump
or attempting to remove pump
from sump.
4