Wiring - Astralpool WATERLIFT Manuel D'instructions

Masquer les pouces Voir aussi pour WATERLIFT:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 37
Installation
3. Make two holes on the surface of the swimming pool edge with a drill using a Ø10 mm bit.
NOTE
Drill the paving with a smaller diameter bit at the end and then drill again with the Ø10 mm bit to
prevent problems with the plug tolerance and subsequent fastening.
4. Use DIN-571 Ø 8x70 metal plugs and screws for fastening. Insert the metal plugs in the holes made
in the paving and place the supplied support plastic plug underneath the lift structure.
5. Insert the screws through the structure fastening holes and screw the structure to the paving.
Fig. 8: Fastening to paving with the plug-screw-support assembly.

6.3.5 Wiring

For the subsequent wiring of the lift to the electric supply cabinet situated in the swimming pool's technical
housing:
1. Make a trench in the paving to house the power supply cable (protected by a corrugated cable tube).
2. Bury the corrugated tube with the cable.
3. Cover with cement.
Fig. 9: Trench to bury the power supply cable.
A: Power supply box location
B: Control box location
Instruction Manual Waterlift rev.0.7 -06/09
15/196

Publicité

Table des Matières
loading

Produits Connexes pour Astralpool WATERLIFT

Table des Matières