1.1 Correspondence table
50 W
24 V
2 A
48 V
The currents (In) shown are at rated output power.
1.2 Environmental specifications
Operating temperature:
-5 °C to +40 °C at 100 % charge.
-5 °C to +50 °C at 75 % charge.
-5 °C to +50 °C at 100 % charge for 50 W to 100 W.
Storage temperature: -25 to +85 °C.
Relative humidity: 20 to 95 %.
Heat capacity consult our website:
Environment class: 1 (according to EN 12101-10)
1.3 Electrical input and output specifications
1.3.1
Network input
single-phase voltage: 195 V to 264 V.
-
frequency: 47 to 63 Hz.
-
class I.
-
neutral systems: TT, TN, IT.
-
Primary current @ 195 V
Circuit breaker to be provided upstream: D curve
1.3.2
Output
Rated voltage
Floating voltage set at half-load and at 25 °C.
The AES version can function without load current
The output current In max. can be used on a
single outlet or distributed among all outlets.
Maximum specified output current that can be
supplied continuously. (C=battery capacity).
Maximum specified output current greater than I
max a, that can be supplied for a short period of
time during which battery charging is not required.
Switching time
75 W
100 W
3 A
4 A
2 A
www.slat.fr
50 W
75 W
100 W
0.4 A
0.5 A
0.75 A
150 W
200 W
6 A
8 A
3 A
4 A
150 W
200 W
1 A
1.5 A
24 V
27.2 V
±0.5 %
Imin = 0
I max a = In –C/20
I max b = In
24
300 W
400 W
12 A
16 A
6 A
8 A
300 W
400 W
600 W
2 A
3 A
4 A
48 V
54.4 V
±0.5 %
In
0s
600 W
24 A
12 A