Télécharger Imprimer la page

Endress+Hauser PROline prowirl 72 Documentation Technique page 15

Masquer les pouces Voir aussi pour PROline prowirl 72:

Publicité

Les langues disponibles

Les langues disponibles

PROline Prowirl 72/73
Measuring system Prowirl 72 / Prowirl 73 remote version
II2G
EX
Zone 0 / Zone 1
Prowirl 73:
A = Transmitter Prowirl 73
1 = Sensor F (DN 15...300)
Standard version
PN 10...40; Cl 150...300; JIS 10...20K
2 = Sensor W (DN 15...150);
Wafer
PN 10...40; Cl 150...300; JIS 10...20K
Prowirl 72:
B = Transmitter Prowirl 72
1 = Sensor F (DN 15...300);
Standard version
PN 10...40; Cl 150...300; JIS 10...20K
2 = Sensor W (DN 15...150);
Wafer
PN 10...40; Cl 150...300; JIS 10...20K
3 = Sensor F (DN 15...150);
High pressure version
PN 64...160; Cl 600; JIS 40K
4 = Sensor F (DN 15...150);
Dualsens
PN 10...160; Cl 150...600; JIS 10...40K
Endress+Hauser
Hazardous area
II3G
Â
Â
À
Esc
-
+
E
Á
A
1, 2
A, B
A, B
1
2
Zone 2
Hazardous area
Transmitter electronics Prowirl 73 resp. 73 in:
II3G EEx nA IIC T1-T6 X
Prowirl 72 resp. 73 standard housing
Cable entries:
Choice of thread for cable entries, M20x1.5 or ½" NPT or
!
G ½" thread.
Note
For ambient and fluid temperature ranges, and temperature
class, see Page 5.
Â
À
Esc
-
+
E
Á
B
1, 2, 3, 4
B
B
3
4
<
Safe area
EX
Page
a
Up
Bksp
Delete
Page
On
# % &
A B C
D E F
1
2
3
Copy
Paste
Hot Key
G H I
J K L
M N O
4
5
6
Insert
+ Hot Key
P Q R S
T U V
W X Y Z
7
8
9
, ( ) '
_ < >
+ * /
.
0
-
375
FIELD COMMUNICATOR
b
c
d
e
F06-7xxxxxZZ-16-xx-xx-xx-003
Safe area
a = HART handheld
DXR 275 resp. DXR 375
b = PLS/DCS or other
devices with active
input
c = HART modem, e.g.
Commubox FXA191
d = PC with configuration
tool
e = Service Interface
FXA 193 (see Page 9)
3

Publicité

loading

Ce manuel est également adapté pour:

Proline prowirl 73