Sigfox Smart Building COMFORT - Guide utilisateur / User guide version V1.0.1
S390
4
S391
4
FR
3.3.2 Sigfox network Registers
The list of registers below allows you to change the network parameters of the device. This list is accessible in PROVIDER mode following execu-
tion of the ATT63 PROVIDER command
These registers must be handled with caution because they could cause problems of communication or of non-compliance with the legislation in
force.
EN
Register
Descrip-
tion
S317
1
Event counter for the button (Digi-
tal Input1)
Event counter for the button (Digi-
tal Input 2)
Encoding
Activation of the respect of the duty
cycle
DISTRIBUTED BY TEXIM EUROPE
Decimal
Default: 0
Min/max: 0– 4294967295
Value reset to 0 with a Power-On reset
Decimal
Default: 0
Min/max: 0– 4294967295
Value reset to 0 with a Power-On reset
Details
Decimal
Default: 1 (on)
Min/max: 0 (off) à 1 (on)
Unit: none
WARNING :
Deactivation of the duty cycle may result in the use of the
product a non-compliance with the conditions of use of the
frequency band therefore a violation of the regulations in
force.
In the case of Duty Cycle deactivation the responsibility is
transferred to the user
Details
Page
68