Raise the cover manually, if you want to use one of the interior connectors, and connect the cable into the
desired socket. If you want to use one of the exterior connectors, open the protective covers and connect
the charging cable.
Depending on the connector type used, the operation may vary slightly:
Connector type
CEE 7/4 Type F (Schuko)
CEE 7/7 (Schuko)
IEC 62196-2 Type 2
IEC 62196-2 Type 3A
The station locks the cover when it is completely closed and starts to supply energy to the vehicle, switching to the
charge status.
Ending the charge process
4.
To conclude the charge cycle, pass the cart to the reader and select the Socket in which you want to
complete the charge process. The station interrupts the electrical supply and unlocks the cover of the
receptacle or the connector.
5.
Open the cover, if using one of the interior connectors, remove the connector and close the cover. The
station will lock the cover and return to the awaiting vehicle status.
Loss of power
The station has an auxiliary supply that allows basic operations to be carried out when faced with a loss of
electricity supply. In such a situation the station indicates this anomaly on the display.
44
Connection detection
Automatic detection after lowering the cover
Automatic detection after lowering the cover
Instant automatic detection
Instant automatic detection
Regulation governing the charge
sequence
IEC61851
IEC61851
IEC61851
IEC61851
ABA2020IQM01_B - Installation and Operation Manual