AFTER USE - WET PICK UP
1
Step down on the Squeegee Raise/Lower Pedal (4) to raise the
Squeegee (Air Scoop only). Turn the Main Power Switch (1) OFF and
unplug the Power Cord (6).
2
Move the machine to a designated waste water "Disposal Site".
3
Remove the Drain Hose (5) from its hanger, direct the end of the hose
to a proper disposal area and remove the plug.
If a floor drain is not available, back the machine up to a toilet and remove
the Tip-and-Pour Recovery Tank Drain Plug (11). Disconnect the
Recovery Hose (8) and the Vac Motor Hose (12). Stand at the front of
the machine and lift up on the front of the Recovery Tank (3) until all of
the waste water has drained into the toilet bowl, reinstall the plug (11).
4
Remove the Dome Lid (2) from the Recovery Tank (3) and rinse the tank
with warm water.
5
Remove the Squeegee (9) or Wand and Recovery Hose (8) and rinse
them in warm water.
6
Set the Dome Lid (2) on the tank so that one corner of the lid is pointing
forward. This will allow the tank to air out.
7
Wipe the machine with a damp cloth. Check the Maintenance Schedule
and perform any required maintenance before storage.
8
Store the machine indoors in a clean, dry place.
AFTER USE - DRY PICK UP
1
Turn the Main Power Switch (1) OFF and unplug the Power Cord (6).
Remove the Dome Lid (2) from the Recovery Tank (3).
2
Remove the Dry Container System and shake out, brush off and vacuum
out for normal up keep.
3
Reinstall the Dry Container System in the Recovery Tank (3).
4
If you are using the optional Filter Assembly System, remove the Dry
Filter and shake or wash out.
5
Reinstall the Dome Lid (2) on the Recovery Tank (3).
6
Wipe the machine with a damp cloth. Check the Maintenance Schedule
and perform any required maintenance before storage.
7
Store the machine indoors in a clean, dry place.
TECHNICAL SPECIFICATIONS
Model
Model Number
Voltage/frequency
Rated Power
Protection Class (electrical)
Protection grade (mec, moist, dust)
Sound Pressure Level (at 1.5m)
Weight
Vibration at the Hand Controls
Sprite AS 12
56209220
V/Hz
100V / 50-60Hz
W
630
N/A
dB(A)/20µPa
71.8
lbs / kg
71/31.9
m/s
2
<2.5m/s
2
LUBRICATION
Lubricate the caster swivels and the squeegee raise / lower pivot points with light
machine oil.
VACUUM MOTOR BRUSHES
Have your Advance Dealer check the carbon motor brushes once a year or after
500 operating hours.
IMPORTANT !
Motor damage resulting from failure to service the carbon brushes
is not covered under warranty. See the Limited Warranty State-
ment.
CAUTION !
Unplug the Power Cord (6) before performing any machine
maintenance.
MAINTENANCE SCHEDULE
Maintenance Item
Clean the Recovery Tank
Clean the Float Screen
Clean the Squeegee
Clean Dry Container System
Inspect Tanks and Hoses
Lubrication
Inspect and Clean Vac Motor
Inlet and Outlet Filters
*Check Vacuum Motor Brushes
*Have your Advance Dealer check the carbon motor brushes once a year or
after 500 operating hours.
Sprite 12/16
Sprite AS 12HP
Sprite AS 12/16
56209071/56209072
56209225
56209091/56209092
100V / 50-60Hz
120V / 50-60Hz
870
800
N/A
N/A
71.8
71.8
72/32.4
66/29.7-71/31.9
72/32.4-77/34.6
<2.5m/s
2
<2.5m/s
FORM NO. 56041353 / SPRITE / SPRITE AIR SCOOP - 11
Daily
Monthly
X
X
X
X
X
X
X
Sprite 12/16HP
Sprite AS 12/16HP
56209123/56209124
56209170/56209169
120V / 50-60Hz
1,000
N/A
71.8
67/30.1-72/32.4
73/32.8-78/35.1
2
<2.5m/s
2
Yearly
X
Sprite 12
Sprite AS 12
56209144
56209199
240V / 50-60Hz
1,150
IP 34
71.8
65/29.2
71/31.9
<2.5m/s
2

Publicité

loading