Storage
CAUTION
In order to prevent accidents or injuries, keep in mind
the weight of the appliance when selecting a storage lo-
cation for it (see Specifications).
2.997-100.0
Braided hose set
6.997-346.0
Spiral hose, by the meter,
25 m, 1"
2.645-247.0
Hose PrimoFlex, 50 m, 1"
DANGER
Risk of mortal danger on account of electric shock!
To avoid risks, all repairs and replacement of spare parts may only be carried out by the authorised customer service
personnel.
Fault
Pump runs but does not transport
Pump does not run or suddenly
comes to a standstill during opera-
tions
Pumping capacity is reducing
Pumping capacity too low
Quick-Connect cannot be opened or
closed.
The pump is running although there is
no water contact with the level sensor
Completely drain the pump and allow it to dry.
Store the pump in a frost-free place.
Special accessories
Flexible 1 1/4" braided hose with hose clamp (30 - 40 mm) with wing
screw for a connection without tools.
Especially recommendable for the immersion pumps when remov-
ing large water quantities.
Max. operating pressure: 5 bar
By the meter for cutting hoses to individual lengths.
Phthalate-free 1" garden hose for draining away the water.
Troubleshooting
Cause
Air in the pump
Suction area blocked
Water level below the minimum fluid
level
Power supply interrupted
Thermal protection switch has
switched off the pump due to over-
heating
Dirt particles have got jammed into
the suction area
Level sensor stops pump
The level sensor does not react as it
is soiled
Suction area blocked
The pumping capacity depends on
the flow height, hose diameter and
hose length.
Soiling in the plug system.
The level sensor does not react as it
is soiled
The switch is on manual operation
(MAN)
– 6
EN
Storing the pump
Remedy
Unplug and plug in the mains plug of
the pump repeatedly until the fluid is
drawn
Pull out the mains plug and clean the
suction area
Immerse, whenever possible, the
pump deeper into the feed fluid or
proceed as described in Chapter Op-
eration.
Check fuses and electrical connec-
tions
Pull out the mains plug, let the pump
cool down, clean the suction area,
prevent dry running
Pull out the mains plug and clean the
suction area
Check the position of the level sensor
and correct it if necessary.
The pump stops 15 s after the level
sensor has no water contact any-
more.
Clean the level sensor.
Pull out the mains plug and clean the
suction area
Observe the maximum delivery
height, see technical data. If neces-
sary, use a larger hose diameter or a
shorter hose length.
Remove and clean clip.
Clean the level sensor.
Set the switch to automatic mode
(AUTO).
17