Illustration
NOTICE
In order for the pump to draw independently, the fluid
level must be at least 50 mm (SP 7 Dirt Inox) or 7 mm
(SP 6 Flat Inox).
The pump can pump up to a residual fluid height of
35 mm (SP 7 Dirt Inox) or 1 mm (SP 6 Flat Inox).
Automatic venting device
Illustration
With a low fluid level, possibly drawn air or air that is
present in the pump escapes via the automatic venting
device. In addition, fluid may leak at this spot.
If the pump has suction problems with a low fluid level,
unplug and plug in the mains plug repeatedly in order to
support the suction process.
Automatic operation
Illustration
NOTICE
In the automatic mode, the level sensor automatically
controls the pumping operations.
As soon as the level sensor has contact with the rising
feed fluid the pump switches on.
The pump switches off as soon as the level sensor loses
contact with the falling feed fluid and an after-running
time of 15 s has passed.
For switch-on height / switch-off height see the following
table:
Switch-on points SP 6 Flat Inox SP 7 Dirt Inox
With pre-filter, de-
pending on the po-
sition of the level
sensor
Without pre-filter
NOTICE
Ensure that the pump is level.
Otherwise it can happen that the level sensor does not
lose the fluid contact and the pump runs dry.
Push the level sensor to the desired switch-on
height (contact with feed fluid).
NOTICE
The higher the level sensor is adjusted, the higher the
switch-on and switch-off point.
See the following table for application examples:
Min / Max
Shaft with a diame-
ter < of approx.
1 m (e.g. drainage)
16
General
55 - 240 mm
55 - 240 mm
1 - 185 mm
-
SP 6 Flat Inox SP 7 Dirt Inox
Level sensor in
Level sensor in
the upmost po-
the upmost posi-
sition
tion
-
Pre-filter flaps
closed (protec-
tion against soil-
ing)
Min / Max
Swimming pool,
pond or the like
Set the switch to automatic mode (AUTO).
Insert the mains plug into the socket.
NOTICE
In manual operation the pump remains switched on
continuously.
Illustration
Set the switch to manual operation (MAN).
Insert the mains plug into the socket.
ATTENTION
Risk of damage! Dry running leads to increased wear;
never leave the pump unattended during manual oper-
ation. Unplug immediately in case of dry running
Finish operation
NOTICE
Soiling can deposit and lead to malfunctions.
Pump clear water or thoroughly rinse the pump af-
ter every use.
This especially applies after pumping chlorinated
water or other liquids that leave residue.
Disconnect the main plug from the socket.
The pump is maintenace-free.
CAUTION
In order to prevent accidents or injuries, keep in mind
the weight of the appliance during transport (see Spec-
ifications).
Lift and carry the pump on the carrying handle.
If you want to transport the appliance on a vehicle
secure it from slipping.
– 5
EN
SP 6 Flat Inox SP 7 Dirt Inox
Level sensor in
Level sensor in
the lowest posi-
the lowest posi-
tion
tion
Start pumping
Pre-filter flaps
operations with
closed (protec-
pre-filter or
tion against soil-
folded out sup-
ing)
port legs
Continuation
-
pumping oper-
ations without
pre-filter and
folded in sup-
port legs (resid-
ual fluid height
1 mm is
reached)
Manual operation
Maintenance
Transport