Burner and nozzle specifications
GB
Table 1
TYPE OF GAS
USED
NATURAL GAS
(Methane)
G20
LIQUEFIED
PETROLEUM GAS
(Butane)
G30
LIQUEFIED
PETROLEUM GAS
(Propane)
G31
Type of gas used
G20 20 mbar
G30 28-30 mbar
G31 37 mbar
ELECTRIC SUPPLY: 220-240V~ 50/60Hz 0,6W
S
R
S
THA 752 IX/I
8
TYPE OF
NOZZLE
BURNER
THERMAL
FLOW RATE
Rapid
115Y
Semi-Rapid
95Z
Auxiliary
72X
Rapid
85
Semi-Rapid
63
Auxiliary
50
Rapid
85
Semi-Rapid
63
Auxiliary
50
Model configuration
5 BURNERS
2R - 2S -1A
2R - 2S -1A
2R - 2S -1A
R
A
RATED
RATED
CONSUMPTION
kW
3.00
286 l/h
1.65
157 l/h
1.00
95 l/h
3.00
218 g/h
1.65
120 g/h
1.00
73 g/h
3.00
214 g/h
1.65
118 g/h
1.00
71 g/h
Rated thermal
ow rate (kW)
consumption
10.30
10.30
10.30
CATEGORY II2E+3+
REDUCED
GAS PRESSURE
HEAT
CAPACITY
kW
min.
0.75
0.40
17
0.40
0.75
0.40
20
0.40
0.75
25
0.40
0.40
Total rated
Air required (m³) for
burning 1 m³ of gas
981 l/h
9.52
749 g/h
30.94
736 g/h
23.80
mbar
rat.
max.
20
25
28-30
35
37
45